20 | IX Series Quick Start Programming Guide
Use the drop-down menu under Output Time Range to select
either 200-2000(msec) or 3-600(sec), then use the Output Time
section to enter the desired value.
Output Time Range and Output Time
Click the Update button save
the changes.
Update
Timer Settings
Getting Started
The call-in, communication, and door release timers are found across several sections within Support Tool. The following
steps will show their location, and give a simple example of adjusting the respective setting.
Door Release Output Timer
To adjust the amount of time the door release relay output activates, expand Option Input / Relay Output Settings and click
Relay Output.
Call Timeout
To adjust the time a station will call-in to another station before ending, expand Call Settings and click Call Origination.
Scroll RightScroll Right
Under Call Timeout, select the desired
duration between 10 and 600 seconds.
Call Timeout
Click the Update button save
the changes.
Update
The setting le needs to be uploaded to each station
for these settings to take eect. Refer to page 12
for more details on this process.
Upload:
The setting le needs to be uploaded to each station
for these settings to take eect. Refer to page 12 for
more details on this process.
Upload:
Use the drop-down menu to
Enable Option Relay Control.
Option Relay Control