6 | IXG Commercial Quick Start Programming Guide
Site Settings (continued)
The IXG Series can use di󰀨erent unit types to support a variety of applications. Here are some common use
cases and solutions to achieve those goals.
Sample Commercial System Layouts
Single O󰀩ce (1 Door Station, 1 Master Station, 8 Mobile Apps)
For this size of o󰀩ce, everything can be placed in a single commercial unit.
Single O󰀩ce (3 Door Stations, 1 Master Station, 8 Mobile Apps)
To accomodate more than two doors calling to a single o󰀩ce, place the master station and mobile apps in a
commercial unit, and the three door stations in an outside area.
To nish conguring the
stations in the Outside Area and
Commercial Unit for calling, see
Station Partitioning on page 13.
Multiple O󰀩ces (1 Door Station, 1 Master Station, 1 Guard Station)
A door station in an outside area can call masters in multiple units at the same time. The main restriction is
that only the mobile apps from one unit can called. These call settings can be fully congured by following the
Station Partitioning section on page 13.