Questions and Answers

  • B
    Barbara BentleyAug 15, 2025
    Why has my Airmaster Air Compressor stopped and will not start?
    • G
      Gregory Ross DDSAug 16, 2025
      If your Airmaster Air Compressor has stopped and won't start, there are a few potential causes: * **Bad electrical connections:** Check all electrical connections, cleaning and tightening them if necessary. * **Overload cutout switch tripped:** Switch off the compressor, wait approximately 5 minutes, then press the reset button and switch it back on. * **Motor windings burnt out:** Contact your dealer for a replacement motor.
  • I
    icrawfordAug 18, 2025
    Why my airmaster TIGER 11/260 does not reach the set pressure and overheats easily?
    • C
      carrolljanetAug 18, 2025
      If your Airmaster Air Compressor does not reach the set pressure and overheats easily, this could be due to a blown compressor head gasket or a broken valve. Return the compressor to your nearest service agent for repair.
  • K
    kathryn56Aug 22, 2025
    How to fix air leaking from the non-return valve when the Airmaster Air Compressor is not running?
    • H
      Hannah WebbAug 22, 2025
      If air is leaking from the non-return valve of your Airmaster Air Compressor when it's not running: 1. Drain the receiver completely of air. 2. Remove the valve end plug. 3. Carefully clean the valve seat and the gasket. 4. Reassemble.
  • T
    Travis MoralesAug 25, 2025
    What to do if airmaster TIGER 11/260 Air Compressor is very noisy and makes a metallic knocking sound?
    • D
      David EspinozaAug 25, 2025
      If your Airmaster Air Compressor is very noisy and makes a metallic knocking sound, the compressor may be damaged and require an overhaul. Return the compressor to your nearest service agent.
  • L
    Lisa FaulknerAug 28, 2025
    How to fix air pressure if the regulator will not adjust on my airmaster TIGER 11/260?
    • N
      Nancy OwenAug 28, 2025
      If the air pressure from the regulator on your Airmaster Air Compressor will not adjust, the diaphragm within the regulator body may be broken. Replace the regulator.
  • K
    Kathleen BrownAug 30, 2025
    What to do if my Airmaster Air Compressor has stopped and does not start?
    • C
      Crystal McbrideAug 30, 2025
      If your Airmaster Air Compressor has stopped and won't start, it could be due to bad electrical connections. Check the connections, and if needed, clean and tighten them. Alternatively, the overload cutout switch may have tripped. In this case, switch off the compressor, wait about 5 minutes, then press the reset button and switch it back on. In a worst case scenario, the motor windings might be burnt out, in which case you should contact your dealer for a replacement motor.
  • S
    Stephen PriceSep 2, 2025
    Why is air leaking from the airmaster TIGER 11/260 Air Compressor non-return valve when it's off?
    • C
      Charles JordanSep 2, 2025
      If air is leaking from the non-return valve when your Airmaster Air Compressor is not running, it indicates a faulty non-return valve. To fix this, first, completely drain the receiver of air. Then, remove the valve end plug and carefully clean the valve seat and the gasket before reassembling.
  • J
    Jonathan AguilarSep 5, 2025
    How to fix air pressure regulator on airmaster TIGER 11/260?
    • R
      Rebecca BarkerSep 5, 2025
      If the air pressure from the regulator on your Airmaster Air Compressor will not adjust, it's likely that the diaphragm within the regulator body is broken. The solution is to replace the regulator.
  • G
    garrettjoshuaSep 9, 2025
    Why is my airmaster TIGER 11/260 making a metallic knocking sound?
    • A
      anthonybruceSep 9, 2025
      If your Airmaster Air Compressor is very noisy and makes a metallic knocking sound, it indicates that the compressor is damaged and needs an overhaul. Return the compressor to your nearest service agent.
  • B
    Brian RaySep 12, 2025
    What to do if my airmaster TIGER 11/260 Air Compressor overheats and doesn't reach set pressure?
    • L
      Lindsay Cordova MDSep 12, 2025
      If the Airmaster Air Compressor does not reach the set pressure and overheats easily, it could be due to a blown compressor head gasket or a broken valve. Return the compressor to your nearest service agent.