Do you have a question about the Airwell AWSI-HDDE009-H11 and is the answer not in the manual?
Cooling Capacity | 9000 BTU/h |
---|---|
Energy Efficiency Ratio (EER) | 3.21 |
Power Supply | 220-240V, 50Hz |
Noise Level (Indoor) | 38 dB(A) |
Refrigerant | R410A |
Operating Temperature (Heating) | 0-30°C |
Weight (Indoor Unit) | 8 kg |
Weight (Outdoor Unit) | 25 kg |
Type | Split Air Conditioner |
Dimensions (Outdoor Unit) | 700 x 540 x 250 mm |
Overview of the HDDE series mono-split DCI inverter air conditioner and its features.
Highlights the main technological innovations and benefits of the air conditioning units.
Describes the components and design of the wall-mounted indoor unit.
Explains the microprocessor and remote control system for operating the unit.
Details the components and construction of the outdoor units.
Provides essential information regarding the connection of tubing between units.
Lists the manuals included with each unit for installation and operation.
Shows the compatibility between different indoor and outdoor unit models.
Specifies the operational temperature and voltage limits for cooling and heating.
Provides detailed dimensions for indoor units HDDE009, HDDE012, HDDE018, and HDDE024.
Presents the dimensions for outdoor units YDDE009 and YDDE012.
Details the dimensions for outdoor units YDDE018 and YDDE024.
Illustrates the methods for measuring sound pressure levels for different unit types.
Details the sound pressure level spectrum as measured according to specific figures.
Provides the wiring schematic for indoor units HDDE009 and HDDE012.
Shows the wiring schematics for indoor unit HDDE024 and outdoor unit YDDE009.
Presents wiring schematics for outdoor units YDDE012, YDDE018, and YDDE024.
Illustrates the refrigeration cycle for different model combinations.
Details the electronic control system and its functions.
Explains the PI control scheme for managing compressor frequency.
Describes the control logic for the indoor fan speed.
Details the operation of the Electronic Expansion Valve (EEV) and capillary.
Specifies the unit's behavior and fan control during heating mode.
Explains automatic mode selection based on room temperature.
Describes the operation and states of the air outlet louvers.
Details the sleep function for energy saving and the I-Feel temperature sensing.
Outlines various protection codes and conditions that stop unit operation.
Lists error codes associated with temperature sensor failures.
Explains the display, indicators, and buttons of the indoor unit.
Information regarding the test mode for system checking.
Safety precautions and initial checks for electrical and control issues.
Interprets error codes displayed by the unit for malfunction diagnosis.
Procedures for checking system pressures and thermodynamic measures.
Simple steps for verifying mains voltage, power input, fan motor, and compressor.
Provides the resistance-temperature chart for Room/Outdoor Air Temperature sensors.
Presents the resistance-temperature chart for Indoor/Outdoor Coil Temperature sensors.
Shows the resistance-temperature chart for the Compressor Top Temperature sensor.
Visual breakdown of indoor units HDDE009 and HDDE012.
Lists spare parts for the HDDE009 indoor unit with part codes and quantities.
Visual breakdown of the HDDE018 indoor unit.
Provides spare parts list for the HDDE018 indoor unit.
Visual breakdown of the HDDE024 indoor unit.
Lists spare parts for the HDDE024 indoor unit.
Visual breakdown of outdoor units YDDE009 and YDDE012.
Provides spare parts list for the YDDE009 outdoor unit.
Visual breakdown of the YDDE018 outdoor unit.
Lists spare parts for the YDDE018 outdoor unit.
Visual breakdown of the YDDE024 outdoor unit.
Provides spare parts list for the YDDE024 outdoor unit.
Step-by-step guide for servicing the indoor units.
Step-by-step guide for servicing the outdoor units.