HJD DCI Series
 – 201
REFRIGERANT
R410A
HEAT PUMP
SM HJD DCI 1-A. GB
Indoor Units Outdoor Units
AW6,-HJD009-N11 AWAU-YBDE009-H11
AW6,-HJD012-N11 AWAU-YBDE012-H11
AW6,-HJD018-N11 AWAU-YBDE018-H11
AW6,-HJD024-N11 AWAU-YBDE024-H11
ECO DESIGN
A
WSI-HJD030-N11
A
WAU-YBDE030-H11

Questions and Answers

  • A
    Alexander SosaAug 19, 2025
    Why is the cooling capacity of my Airwell AWSI-HJD018-N11 not sufficient?
    • K
      Kristina LaneAug 19, 2025
      If your Airwell Air Conditioner isn't cooling sufficiently, several factors could be the cause: * The unit size may not be adequate for the room's load. Check if a larger unit is needed. * The piping size might not match the system specifications. Verify correct installation, diameter size and total length according to unit specifications. * There may be a refrigerant leak. Check the refrigeration system. * There may be a refrigerant clog. Inspect and repair any clogging, especially near the EEV. * Electronics control problem or protection. Check for any fault code shown on display board and act accordingly. * Compressor failure. Check if fault code # is shown on display board. If so, fix the problem according to 13.5.7 or replace driver.
  • C
    Caleb CruzAug 21, 2025
    What to do if my Airwell AWSI-HJD018-N11 Air Conditioner indoor unit does not respond to the remote control?
    • A
      Anthony LawsonAug 22, 2025
      If your Airwell Air Conditioner indoor unit isn't responding to the remote control, first check the remote control batteries. If that doesn't solve the problem, and if the cause is 'Check continuity of each wire of the display wires/pins with Ohm meter', replace the display box or indoor Electronic Assembly.
  • J
    Joshua HallAug 25, 2025
    Why is the heating capacity of my Airwell AWSI-HJD018-N11 not sufficient?
    • E
      Erica HayesAug 25, 2025
      If your Airwell Air Conditioner isn't heating sufficiently, it could be due to: * Reverse valve. Check reversing valve operation. * Deicing not performed well (during low outdoors temperatures). Check OCT and OAT thermistors fault codes (#1 and 4). Check OCT thermistor if connected well to pipe. Check OAT thermistor if connected well. Check the thermistors operation.
  • E
    Elizabeth SmithAug 26, 2025
    Why is my Airwell AWSI-HJD018-N11 outdoor unit coil freezing in heat mode?
    • D
      Darius SaundersAug 26, 2025
      If the outdoor unit coil of your Airwell Air Conditioner is freezing in heat mode and the base is blocked with ice: * It could be due to hard conditions of low temperatures and high humidity. Check that there are no obstructions to the outdoor unit coil air inlet. * Check that all holes in bottom of outdoor unit base are open and clean from dirt. * Check OCT and OAT thermistors. * Connect base heater.
  • M
    michelle97Aug 27, 2025
    What to do if there is water leakage from my Airwell AWSI-HJD018-N11 indoor unit?
    • S
      spencermichelleAug 28, 2025
      If you notice water leaking from your Airwell Air Conditioner's indoor unit, the most likely cause is a blocked drainage tube. Inspect the drainage tube and clear any blockage to resolve the issue.
  • R
    Robert CookAug 30, 2025
    Why does the fuse keep burning in my Airwell Air Conditioner indoor unit controller?
    • S
      Sharon HansenAug 30, 2025
      If the fuse in your Airwell Air Conditioner's indoor unit controller has burned out, it could be due to a short circuit between wires. Inspect for any cuts or exposed supply wires, or miss-wiring. Another cause could be failure of the indoor unit fan motor, so check the motor and capacitor for any cuts or exposed wires. If the problem persists, replace the fuse.
  • T
    teresagibsonSep 1, 2025
    How to troubleshoot an Airwell Air Conditioner when the indoor fan won't start?
    • Z
      zachary47Sep 1, 2025
      If the indoor fan of your Airwell Air Conditioner isn't starting, but the louvers are open and the green LED is on, it could be due to several reasons: * If the unit is in heat mode and the coil isn't warm yet, change to Cool or Fan mode. * There may be a failure of the indoor unit fan motor. Check the motor and capacitor for any cuts or exposed wires. * There could be a problem with the controller or motor capacitor. Change to high speed and check the power supply to the motor is higher than 220VAC. * If still not OK, replace indoor Electronic Assembly.
  • A
    Amy EllisSep 3, 2025
    Why is the display board off on my Airwell AWSI-HJD018-N11 outdoor unit?
    • W
      Wendy FisherSep 3, 2025
      If the display board and LEDs on your Airwell Air Conditioner's outdoor unit are off, it could be due to: * No power supply. Check the supply voltage to main terminals L and N with a voltmeter. * Miss-wiring. Check all supply wiring to the controller and terminals according to the wiring diagram. * Loose connection. Check all power wiring connections. * Burnt fuse. Check the fuse on the main board. * If still not OK, replace main board.
  • C
    Christina HernandezSep 5, 2025
    Why is the power indicator LED off on my Airwell Air Conditioner indoor unit?
    • A
      anthonyriveraSep 5, 2025
      If the red LED power supply indicator on your Airwell Air Conditioner indoor unit isn't lighting up, it could be due to: * No power supply. Check the supply voltage to main terminals L and N with a voltmeter. * Miss-wiring. Check all supply wiring to the controller and terminals according to the wiring diagram. * Loose connection. Check all power wiring connections. * Display and display cable. Check continuity of each wire of the display wires/pins with an Ohm meter. * If still not OK, check if the fuse is burnt.
  • J
    Juan CraigSep 7, 2025
    What to do if the compressor of my Airwell Air Conditioner does not start?
    • S
      Sylvia SheltonSep 7, 2025
      If the compressor of your Airwell Air Conditioner isn't starting, it could be due to: * One or some components are not operating well. Check for any fault code shown on the display board and act accordingly. * Electronics control problem or protection. * PFC Chock coil. Check the PFC Chock coil. * Driver failure. Check if fault code # is shown on display board. If so, fix the problem according to 13.5.4 or replace driver. * If still not OK, replace compressor.

Summary

Introduction to HJD DCI Series

General Overview of HJD DCI Series

Describes the HJD DCI INVERTER split wall mounted range and its key features.

Key Technological Innovations

Lists the main technological advancements in the HJD DCI series.

Indoor Unit Features and Specifications

Details the characteristics, filtration, ionizer, and control of indoor units.

Outdoor Unit and Accessories

Covers outdoor unit installation, accessories, and documentation.

Indoor and Outdoor Unit Matching Table

Provides a table for matching compatible indoor and outdoor units.

Product Data Sheet

HJD009 DCI Specifications

Presents detailed technical specifications for the HJD009 DCI model.

HJD012 DCI Specifications

Presents detailed technical specifications for the HJD012 DCI model.

HJD018 DCI Specifications

Presents detailed technical specifications for the HJD018 DCI model.

HJD024 DCI Specifications

Presents detailed technical specifications for the HJD024 DCI model.

HJD030 DCI Specifications

Presents detailed technical specifications for the HJD030 DCI model.

Rating Conditions and Operating Limits

Operating Limits Definition

Defines the operational temperature and voltage limits for the system.

Outline Dimensions

Indoor Unit Dimensions (HJD009;012)

Provides dimensional drawings and measurements for HJD009/012 indoor units.

Outdoor Unit Dimensions (YBDE009;012)

Provides dimensional drawings and measurements for YBDE009/012 outdoor units.

Indoor Unit Dimensions (HJD018;024)

Provides dimensional drawings and measurements for HJD018/024 indoor units.

Outdoor Unit Dimensions (YBDE018;024)

Provides dimensional drawings and measurements for YBDE018/024 outdoor units.

Indoor Unit Dimensions (HJD030)

Provides dimensional drawings and measurements for HJD030 indoor units.

Outdoor Unit Dimensions (YBDE030)

Provides dimensional drawings and measurements for YBDE030 outdoor units.

Performance Data and Pressure Curves

HJD009; YBDE009 DCI Performance Data

Details cooling/heating capacity and correction factors for HJD009/YBDE009.

Tubing Length Capacity Correction Factors

Illustrates how tubing length impacts cooling and heating capacity.

HJD012; YBDE012 DCI Performance Data

Details cooling/heating capacity and correction factors for HJD012/YBDE012.

HJD018; YBDE018 Performance Data

Details cooling/heating capacity and correction factors for HJD018/YBDE018.

HJD024; YBDE024 Performance Data

Details cooling/heating capacity and correction factors for HJD024/YBDE024.

HJD030; YBDE030 Performance Data

Details cooling/heating capacity and correction factors for HJD030/YBDE030.

Cooling Pressure Curves

Presents suction and discharge pressure curves for cooling operation.

Heating Pressure Curves

Presents suction and discharge pressure curves for heating operation.

Sound Level Characteristics

Indoor Unit Sound Testing

Describes the test scheme and sound pressure levels for indoor units.

Outdoor Unit Sound Testing

Describes the test scheme and sound pressure levels for outdoor units.

Electrical Data

Single Phase Unit Electrical Data

Provides electrical data, currents, and wiring specifications for single-phase units.

Wiring Diagrams

HJD 009;012; YBDE 009;012 DCI Wiring

Wiring diagrams for HJD 009/012 indoor and YBDE 009/012 outdoor units.

HJD018 Indoor Unit Wiring

Wiring diagram for the HJD018 indoor unit.

YBDE018 Outdoor Unit Wiring

Wiring diagram for the YBDE018 outdoor unit.

HJD024 DCI Indoor Unit Wiring

Wiring diagram for the HJD024 DCI indoor unit.

YBDE024 Outdoor Unit Wiring

Wiring diagram for the YBDE024 outdoor unit.

HJD030 DCI Indoor Unit Wiring

Wiring diagram for the HJD030 DCI indoor unit.

YBDE030 DCI Outdoor Unit Wiring

Wiring diagram for the YBDE030 DCI outdoor unit.

Tubing Connections

Refrigeration Diagrams

Heat Pump Models Refrigeration Cycle

Illustrates the refrigeration cycle for heat pump models.

Electrical Connections

HJD009, 012, 018 DCI Connections

Details electrical connection points for HJD009, 012, 018 DCI models.

HJD030 DCI Electrical Connections

Details electrical connection points for HJD030 DCI model.

Control System Overview

Technical Abbreviations

Defines technical abbreviations used throughout the control system section.

Product Overview and Controllers

System architecture, block diagram, and controller details.

Key Control Features

Details on compressor, fan, EEV, sensors, and other control features.

General Operating Rules and Communication

Covers power up sequence, communication, and general operating rules.

System Configuration and Thermistor Tests

Procedures for system configuration tests and thermistor fault analysis.

Indoor Unit Control Modes and Logic

Explains Load Calculation, FAN, Cool, Heat, Auto, Dry, and Sleep modes.

Unit Controls and Indicators

Describes controls and indicators for indoor and outdoor units.

Menus and Navigation Interface

Details menu structure, navigation, and interface descriptions.

Run Mode Operation

Mode Setting Options

Defines the available operation modes: STBY, COOL, and HEAT.

Compressor Speed Control Logic

Explains compressor speed control, limitations, and shutdown cases.

EEV Control Mechanisms

Details EEV general rules, initialization, operation range, and correction.

Outdoor Fan Speed Control Logic

Explains OFAN operation, night mode, failure behavior, and protection.

Thermodynamic Protections

Protection Types and Status

Lists protection types (e.g., Overcurrent) and their status.

Deicing Operation Procedures

Details deicing starting conditions and protection procedures.

High;Low Pressure Protection

Explains high and low pressure protection mechanisms.

Technician Test Mode

Entering Technician Test Mode

Procedure for entering the technician test mode.

Technician Test Mode Procedures

Steps for conducting system tests in technician mode.

Exiting Technician Test Mode

Methods for exiting the technician test mode.

User Interface Operations

User Interface Description and Keys

Describes the interface elements, keys, and navigation concept.

Menus and Navigation Interface

Details menu structure, navigation, and interface descriptions.

Jumper and DIP-Switch Settings

IDU Jumper;DIP-Switch Settings

Configuration settings for IDU self-test, compensation, and family selection.

ODU Jumpers and Model Selection

ODU jumper settings for self-test and model selection.

Remote Control DIP Switch Settings

DIP switch configurations for the remote control unit.

System Parameters

General System Parameters

Lists general system parameters applicable to all models.

ODU Model Dependent Parameters

Lists parameters that vary based on the outdoor unit model.

IDU Model Dependent Parameters

Lists parameters that vary based on the indoor unit model.

7-Segment Display Legend

Troubleshooting Guide

Safety Precautions for Troubleshooting

Important safety precautions before performing troubleshooting.

General System Failures and Corrective Actions

Lists common system failures and their corresponding corrective actions.

Refrigeration System Checks

Procedures for checking the refrigeration system's pressures and measures.

Diagnostics Codes and Faults

Details fault codes and diagnostic procedures for units.

Main Parts Checking Procedures

Procedures for checking key components like voltage, driver, motors, and sensors.

Electromagnetic Interference (EMC) Troubleshooting

Guidance on identifying and resolving EMC issues.

Exploded Views and Spare Parts List

Indoor Unit Exploded Views and Parts Lists

Exploded views and spare parts for HJD009/012, HJD018, HJD024, HJD030 indoor units.

Outdoor Unit Exploded Views and Parts Lists

Exploded views and spare parts for YBDE009/012, YBDE018, YBDE024, OU8DCI outdoor units.

Appendix A

Airwell AWSI-HJD018-N11 Specifications

General IconGeneral
TypeSplit System
Cooling Capacity18000 BTU/h
Energy Efficiency Ratio (EER)3.21
Seasonal Energy Efficiency Ratio (SEER)6.1
Coefficient of Performance (COP)3.61
RefrigerantR32
Weight (Outdoor Unit)28 kg
Noise Level (Indoor)42 dB(A)
Power Supply220-240V, 50Hz