Indoor Units Outdoor Units
AWSI-HDD018-H11 AWSI-HED018-H11 AWAU-YDD018-H11
AWSI-HDD024-H11 AWSI-HED024-H11 AWAU-YDD024-H11
NOVEMBER – 2010
REFRIGERANT
R410A
HEAT PUMP
SM HDDHED 2-A.1 GB
Version: 1

Questions and Answers

  • E
    Edwin BurnsAug 19, 2025
    Why is my Airwell AWSI-HDD018-H11 showing over current protection?
    • J
      James ShepherdAug 19, 2025
      The Airwell Air Conditioner might be showing an over current protection error because the supply voltage is unstable, or the supply voltage is too low while the load is too high.
  • S
    srobinsonAug 21, 2025
    Why does my Airwell AWSI-HDD018-H11 have indoor/outdoor coil over heating protection?
    • D
      Donna AndrewsAug 21, 2025
      Your Airwell Air Conditioner might be experiencing indoor or outdoor coil over heating protection because the ambient temperature is too high or the heat exchange is poor, possibly due to a blockage or a bad radiating environment.
  • K
    Kathleen GallegosAug 23, 2025
    Why does my Airwell AWSI-HDD018-H11 have HP switch protection?
    • G
      Gregory LamAug 23, 2025
      HP switch protection in your Airwell Air Conditioner may be triggered by superabundant refrigerant, poor heat exchange (including blockage and bad radiating environment), or too high ambient temperature.
  • S
    Shelly HillAug 26, 2025
    What causes compressor phase DC over current protection in Airwell Air Conditioner?
    • C
      clayabigailAug 27, 2025
      Compressor phase DC over current protection in your Airwell Air Conditioner can be caused by several factors: 1. Abnormal power input voltage. 2. Compressor wiring mistake. 3. Liquid and gas valve are not open. 4. EEV damaged or not proper working. 5. Poor heat exchange. 6. Over charged system.
  • L
    Lynn MartinezAug 28, 2025
    What causes indoor coil defrost protection in Airwell AWSI-HDD018-H11 Air Conditioner?
    • J
      Justin GrayAug 28, 2025
      Indoor coil defrost protection in your Airwell Air Conditioner can be triggered by poor air-return in the indoor unit, abnormal fan speed, or a dirty evaporator.
  • R
    Rachel ThomasAug 30, 2025
    Why is the Hz down on my Airwell AWSI-HDD018-H11 Air Conditioner due to overload?
    • C
      Candice GonzalezAug 30, 2025
      The Hz (Hertz) on your Airwell Air Conditioner might be decreasing due to an overload because the ambient temperature is too high, or the heat exchange is poor, potentially due to blockage or a bad radiating environment.
  • C
    Cheryl HoodSep 2, 2025
    What causes Hz to drop due to over current in Airwell AWSI-HDD018-H11 Air Conditioner?
    • J
      James HillSep 2, 2025
      A drop in Hz (Hertz) due to over current in your Airwell Air Conditioner can be caused by a power supply voltage that is too low, or higher system pressure and overload.
  • R
    reedjohnSep 4, 2025
    Why is the Hz down on my Airwell AWSI-HDD018-H11 Air Conditioner due to CTT over heating?
    • R
      rodneystevensSep 4, 2025
      The Hz (Hertz) on your Airwell Air Conditioner might be decreasing due to CTT (Condenser Top Temperature) over heating because of overload, high temperature, insufficient refrigerant or an EEV problem.
  • Z
    Zachary SimmonsSep 6, 2025
    What causes DC over voltage in Airwell Air Conditioner?
    • T
      turnerkennethSep 6, 2025
      DC over voltage in your Airwell Air Conditioner can be caused by an AC power supply higher than 265V or an outdoor PCB circuit malfunction.
  • V
    vmeltonSep 8, 2025
    What causes RAT failure in Airwell AWSI-HDD018-H11 Air Conditioner?
    • M
      Madison WashingtonSep 9, 2025
      RAT (Room Air Temperature) failure in your Airwell Air Conditioner can be caused by a broken or damaged sensor, or a problem with the PCB temperature detection circuit.

Summary

PRODUCT DATA SHEET

2.1 HDD018;HED018;YDD018 Specifications

Presents detailed technical specifications for the HDD018, HED018, and YDD018 models.

2.2 HDD024;HED024;YDD024 Specifications

Presents detailed technical specifications for the HDD024, HED024, and YDD024 models.

RATING CONDITIONS

3.1 Operating Limits

Details the operating temperature and voltage limits for cooling and heating modes.

PERFORMANCE DATA & PRESSURE CURVES

5.1.1 Cooling Capacity (HDD018;HED018)

Details cooling capacity data for HDD018/HED018 models.

5.1.3 Heating Capacity (HDD018;HED018)

Details heating capacity data for HDD018/HED018 models.

5.2.1 Cooling Capacity (HDD024;HED024)

Details cooling capacity data for HDD024/HED024 models.

5.2.3 Heating Capacity (HDD024;HED024)

Details heating capacity data for HDD024/HED024 models.

WIRING DIAGRAMS

8.1 Indoor Unit Wiring Diagrams

Provides detailed wiring diagrams for indoor units.

8.2 Outdoor Unit Wiring Diagrams

Provides detailed wiring diagrams for outdoor units.

REFRIGERATION DIAGRAMS

9.1 HDD018;HED018;YDD018 Refrigeration Diagrams

Shows the refrigeration circuit for HDD018/HED018/YDD018 models.

9.2 HDD024;HED024;YDD024 Refrigeration Diagrams

Shows the refrigeration circuit for HDD024/HED024/YDD024 models.

CONTROL SYSTEM

11.10 I-Feel Function & 11.11 Protections Overview

Explains the I-Feel function and provides an overview of various protection codes.

11.11.1 to 11.11.10 Detailed Protections

Details specific protection mechanisms like defrost, heating, current, and deicing.

TROUBLESHOOTING

12.1 Electrical & Control Precautions

Provides essential safety precautions before performing electrical and control troubleshooting.

12.1.3 Diagnostics & 12.1.4 Refrigeration Checks

Interprets unit error diagnostics and outlines procedures for checking the refrigeration system.

EXPLODED VIEWS AND SPARE PARTS LISTS

Airwell AWSI-HDD018-H11 Specifications

General IconGeneral
TypeSplit System
RefrigerantR32
Energy Efficiency Ratio (EER)3.21
Coefficient of Performance (COP)3.61
Noise Level (Indoor Unit)42 dB(A)
Air Flow (Indoor Unit)850 m³/h
Power Supply220-240V, 50Hz