Cooling Capacity | 12000 BTU/h |
---|---|
Heating Capacity | 13000 BTU/h |
Power Supply | 220-240V, 50Hz |
Energy Efficiency Ratio (EER) | 3.21 |
Coefficient of Performance (COP) | 3.61 |
Refrigerant | R410A |
Type | Split System |
Air Flow (Indoor) | 500 m3/h |
Operating Temperature (Cooling) | 18°C to 43°C |
Operating Temperature (Heating) | 24 °C |
General description of the multisplit system and its benefits.
Lists key technological innovations and benefits of the air conditioner.
Describes the features and components of the indoor unit.
Explains the control system and remote control features.
Details the installation and components of the outdoor unit.
Information on connecting refrigerant tubing between indoor and outdoor units.
Lists the manuals included with the air conditioning unit.
Shows compatible indoor and outdoor unit combinations.
Details possible indoor unit configurations for specific outdoor units.
Technical data for the YBZ214 outdoor unit, including capacity and power.
Technical data for the YBZ318 outdoor unit, including capacity and power.
Technical data for the HZD009 and HYD009 indoor units.
Technical data for the HZD012 and HYD012 indoor units.
Technical data for the HZD018 and HYD018 indoor units.
Specifies indoor and outdoor conditions for cooling operation.
Specifies indoor and outdoor conditions for heating operation.
Defines the operational temperature and voltage ranges for the unit.
Provides dimensions for HZD009, HZD012, HYD009, HYD012 indoor units.
Provides dimensions for HZD018 and HYD018 indoor units.
Provides dimensions for the YBZ214 outdoor unit.
Provides dimensions for YBZ318 and YBZ430 outdoor units.
Cooling & heating capacity, correction factors for YBZ214.
Cooling & heating capacity, correction factors for YBZ318.
Cooling & heating capacity, correction factors for YBZ430.
Cooling pressure curves for YBZ214 based on outdoor temperature.
Heating pressure curves for YBZ214 based on outdoor WB temperature.
Cooling pressure curves for YBZ318 based on outdoor temperature.
Heating pressure curves for YBZ318 based on outdoor WB temperature.
Cooling pressure curves for YBZ430 based on outdoor temperature.
Heating pressure curves for YBZ430 based on outdoor WB temperature.
Measurement methods and figures for sound pressure level.
Octave band sound pressure levels for various indoor unit models.
Power supply, current, circuit breaker, and wiring details for models.
Wiring diagrams for HZD/HYD series indoor units.
Wiring diagram for the YBZ214 outdoor unit.
Wiring diagram for the YBZ318 outdoor unit.
Wiring diagram for the YBZ430 outdoor unit.
Shows wiring connections between indoor and outdoor units.
Diagram illustrating the refrigerant flow and components within the system.
Guides for bending and connecting refrigerant tubes, including insulation.
Torque values for flare nuts and valve caps, and cap specifications.
Covers abbreviations, compressor frequency, fan control, EEV, and RV.
Details Fan, Cool, Heat, Auto, Dry, and 8 Degree Heat modes.
Lists and explains various protection mechanisms and error codes.
Covers ON/OFF button, display indicators, tests, and forced modes.
Precautions, confirmations, ODU/IDU fault codes, and their meanings.
Procedures for checking voltage, power input, fan motor, compressor, and RV.
Resistance-temperature charts for various sensors.
Resistance-temperature chart for the CTT sensor.
Exploded view diagrams for HYD009/HYD012 and HYD018/HZD018 indoor units.
Spare parts list for the HYD009 indoor unit.
Spare parts list for the HYD012 indoor unit.
Spare parts list for the HZD009 indoor unit.
Spare parts list for the HZD012 indoor unit.
Spare parts list for the HYD018 indoor unit.
Spare parts list for the HZD018 indoor unit.
Exploded view diagram for the YBZ214 outdoor unit.
Spare parts list for the YBZ214 outdoor unit.
Exploded view diagram for the YBZ318 outdoor unit.
Spare parts list for the YBZ318 outdoor unit.
Exploded view diagram for the YBZ430 outdoor unit.
Spare parts list for the YBZ430 outdoor unit.