Type | Split System |
---|---|
Cooling Capacity | 9000 BTU/h |
Energy Efficiency Ratio (EER) | 3.21 |
Power Supply | 220-240V, 50Hz |
Refrigerant | R32 |
Weight (Outdoor Unit) | 25 kg |
Air Flow (Indoor Unit) | 500 m³/h |
Noise Level (Indoor Unit) | 40 dB(A) |
Introduces the YBZ DC inverter multisplit outdoor unit, its general characteristics, and key technological innovations.
Details the wall-mounted indoor unit features and the microprocessor/remote control system.
Covers outdoor unit installation, components, tubing connections, and inbox documentation.
Provides matching tables and indoor unit combination guidelines for system setup.
Presents detailed technical specifications for the YBZ214 outdoor unit.
Lists detailed technical specifications for the YBZ318 outdoor unit.
Provides technical data for HZD009, HZD012, HYD009, HYD012, and HZD018, HYD018 indoor units.
Specifies the standard indoor and outdoor conditions for cooling operation.
Specifies the standard indoor and outdoor conditions for heating operation.
Details the operational temperature and voltage limits for R410A refrigerant.
Shows dimensional drawings for HZD009, HZD012, HYD009, HYD012 indoor units.
Displays dimensional drawings for HZD018 and HYD018 indoor units.
Provides dimensional drawings for YBZ214, YBZ318, and YBZ430 outdoor units.
Presents cooling and heating capacity data, and correction factors for YBZ214.
Presents cooling and heating capacity data, and correction factors for YBZ318.
Presents cooling and heating capacity data, and correction factors for YBZ430.
Displays suction, discharge, and input current curves for YBZ214 cooling and heating.
Displays suction, discharge, and input current curves for YBZ318 cooling and heating.
Displays suction, discharge, and input current curves for YBZ430 cooling and heating.
Illustrates methods for measuring sound pressure level.
Provides sound pressure level spectrum graphs for HZD009/HYD009 cooling and heating.
Provides sound pressure level spectrum graphs for HZD012/HYD012 cooling and heating.
Provides sound pressure level spectrum graphs for HZD018/HYD018 cooling and heating.
Details power supply, max current, circuit breaker, and wiring specifications for outdoor units.
Wiring diagrams for HZD009, HZD012, HYD009, HYD012 and HZD018, HYD018 indoor units.
Wiring diagrams for YBZ214, YBZ318, and YBZ430 outdoor units.
Shows the wiring connections between indoor and outdoor units.
Illustrates the refrigeration circuits for Indoor Coils A, B, C, and D.
Shows connection points on outdoor and indoor units, and tube bending guidelines.
Provides torque specifications and valve cap data for different tube sizes.
Explains the electronic control system, abbreviations, and key control functions.
Details Fan, Cool, Heat, Auto, Dry, and 8 Degree Heat modes.
Lists and explains various protection codes and mechanisms for system safety.
Describes operating the unit via buttons and understanding indoor unit controllers and indicators.
Covers installation tests, forced deicing, and forced operating modes.
Precautions, confirmations, and fault code displays for electrical/control issues.
Guidance on checking refrigeration system pressures and performance.
Procedures for checking mains voltage, power input, fan motor, compressor, and reverse valve.
Presents the resistance-temperature chart for RAT/OAT sensors.
Presents resistance-temperature charts for ICT, OCT, RGT, and RLT sensors.
Presents the resistance-temperature chart for the CTT sensor.
Shows exploded views for HYD009-012 and HYD018, HZD018 indoor units.
Lists spare parts for HYD009, HYD012, HZD009, HZD012, HYD018, HZD018 indoor units.
Shows exploded views for YBZ214, YBZ318, and YBZ430 outdoor units.
Lists spare parts for YBZ214, YBZ318, and YBZ430 outdoor units.