EasyManua.ls Logo

Akai AP-002

Akai AP-002
40 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Vit.
ADJUSTMENT
CHART
CONDITION
Poor
tone
quality
24
1.
Distortion
(when
using
a
new
quality
record)
Faulty
cartridge
Distortion
persists
after
changing
needle
and
confirming
normal
pick
up
arm
opera-
tion.
(Amp
speaker
normal)
Worn
needle
Crackling
sound
even
when
playing
new
record,
Especially
vague
at
high
range
Stylus
pressure
inadequate
Needle
sinks
to
far
into
cartridge
body
during
record
playback
(too
much
pressure)
Sound
completely
distorted.
Needle
jumps
(insufficient
pressure)
Bent
Stylus
A
crunching
sound
exists
and
the
level
of
tight
and
left
differs
greatly.
Also
loss
in
directional
sensitivity.
Sudden
change
in
sound
level
Bust
adhering
to
stylus
tip
Sound
is
vague
or
distortion
exists
EXPLANATION
SOURCE
AND
SYMPTOM
COUNTERMEASURE
Replace
cartridge
Replace
needle.
Readjust
stylus.
Pressure
Replace
stylus.
Clean
stylus
tip.
9.
Hum
Noise
3.
Left/Right
sound
separation
poor
Lead
wire
from
pick
up
and
power
source
wiring
is
too
close
together
Hum
is
altered
by
changing
position
of
lead
wire
Insufficiently
grounded
When
pick
up
arm
or
player
body
is
touched
with
your
hand,
hum
noise
increases.
No
sound
from
side
(or
both
channels)
and
only
a
hum
is
emitted.
Faulty
cartridge
Using
a
monaural
record,
left
right
sound
scatters
and
is
not
emitted
from
the
center.
(Amp
speaker
connections
are
correct)
(Confirm
that
the
plus
&
minus
terminals
are
not
reversed
on
one
side
at
cartridge
output
pin
and
shell
pin
connection)
Check
wire
and
correct.
Check
amp
input
ground-
ing
from
cartridge.
Player
and
amp
connection
Plug
in
pin
plug
cord
per-
fectly.
Replace
cartridge.
4.
Distortion
at
one
CH
only
Bent
pick
up
head
Observe
head
during
record
performance.
Pick
up
arm
rotating
shaft
faulty
Check
pick
up
arm
side
pressure.
At
zero
balance
arm
does
not
move
smoothly
by
means
of
inside
force
canceller,
Faulty
operation
of
AUTO-LEVER
(9)
Is
there
sufficient
loose
play
between
AUTO-LEVER
(9)
and
PLATE-PU-ASSY
(10)
connection
part?
Are
these
parts
bent?
Is
steel
ball
(8)
movement
smooth?
Trip
(5)
function
faulty
Is
there
sufficient
loose
play
at
TRIP
and
CLUTCH
ASSY
(4)
installation?
Are
these
parts
bent?
Replace
pick-up
arm.
Replace
pick-up
arm.
Straighten
or
replace.
Straighten
or
replace.
5.
Absolutely
no
sound
Pin
plug
cord
is
disconnected
or
solder
has
come
off
of
lead
wire
connection.
Confirm
connections
with
tester
Shorted
or
wire
inside
cartridge
Check
cartridge
terminal
DC
resistance
with
tester.
(L-ch,
R-ch)
Correct.
Repiace
cartridge.

Related product manuals