Step
Adjustment
Test Tape
Mode
Adjustment
Result
Remarks
Item
Supply Signal
Point
Bias
Filter
84
kHz from an
FLI0l
(RED)
Minimum
AC
Refer
to
15
REC
Voltmeter
adjustment
oscillator FL201
(RED)
indication
NOTE
7.
MPX
Filter
19
kHz
Filter
19 kHz from an
FLl0l
(BLK)
Minimum
AC
Switch
to
ON
16
REC
Voltmeter
(REAR
Panel)
adjustment
oscillator
FL201 (BLK)
indication Refer
to
NOTES
6,
7.
Chart-I
NOTES: 1.
Dolby
NR Switch
to
OFF
Position.
2.
Except
for
Step
16,
set MPX
Filter
Switch
to
OFF
Position.
3.
Because each
of
these adjustments
is
vital
to
perfect
Dolby
NR
circuit
operation,
ensure
that
they
are
carried
out
with
as few errors as possible.
4. Use
the
following cassette measuring tapes:
LN Tape TDK D C-60
LH
Tape
Maxell
UD
C-60
CrO
2
Tape TDK SA C-60
Metal Tape TDK
MA-C
C-60
5.
If
either
the
distortion
factor
or
the high range frequency characteristics
do
or
not
satisfy
the
specifica-
tions, carry
out
adjustment items 5
to
14 while changing
the
amount
of
high range
compensation
with
the
REC
EQ
coil
(Ll0l
to
104, L201
to
204).
6.
Adjust
the
oscillator's frequency
to
give a frequency
counter
reading
of
19.00
kHz.
7.
Unless
the
core
is
moved unintentionally this adjustment
is
not
necessary.
IX.
CLASSIFICATION
OF
VARIOUS
P.C
BOARDS
1.
P.C BOARD TITLES AND IDENTIFICATION NUMBERS
P.C Board Title
P.C Board
Number
Selector P.C Board
72-1851
LED
P.C Board
72-1852
LED
Ind. P.C Board 72-1853
REC/PB P.C Board
72-1864
OSC P
.C
Board
72-1865
Power
Switch P.C Board
72-1873
Reed Switch P.C Board
72-1639
Chart-2