VIII. OPERATOR MAINTENANCE
To prevent electrical shock hazard the power button must be in the OFF position before cleaning the
Activator.
The operator should never open the back panel or fuse access panel of this activator due to possible
electrical shock hazard. The back panel should only be opened by a qualied electrician who has read
the service and installation manual.
This activator is not hose washable. Clean only as directed above. Spraying with a hose can get water
into the electrical components and cause a short circuit or an electrical shock.
! WARNING !
To prevent damage to the top surface do not use harsh chemicals or under-diluted sanitizers.
Never
use bleach or solutions containing bleach to clean the stainless steel portions of the activator. The use of
this type of product can induce rusting.
! CAUTION !
SANITATION AND CLEANING PROCEDURES
1. Because the top surface remains relatively cool soil on the top of the activator will not "cook" onto
the top resulting in a quick and easy cleanup.
2. The Heat On Demand
®
Ultra activator should be cleaned and sanitized after each day's use or as
necessary by the following method.
a. Wipe the top and sides with a clean damp cloth using warm water and mild dishwashing deter-
gent. (Abrasive pads are not recommended for cleaning)
b. Use a soft nylon brush on any food soil and in corner areas.
c. Dry thoroughly with a clean dry cloth to remove moisture.
d.
Inspect and clean the air intake lter (see Section IX Parts Illustration)
located on the bottom of the Activator in the front with warm water and
mild detergent once each month or more frequently if it is heavily soiled.
To remove the air intake lter turn the activator off and disconnect it from
the power source. Pull the lter from the bottom front of the appliance.
No tools are necessary. The air intake lter may be immersed in water or
run through a dish machine. Insure that it is thoroughly dry before placing
it back in the activator
Do not operate activator with the air intake lter removed. Foreign particles could enter the activator and
cause an electrical failure. If the activator is operated without the air lter in place it is possible for a person
to stick their ngers in the moving fan blade and cause personal injury.
! WARNING !