IX. TROUBLE SHOOTING
E02
Base too hot or base has already been heated
Action Check base temperature
E03
Heat sink temperature too high
Action Check for air ow at back of unit air lter obstruction or heat sink fan for
failure
E04
Coil overheating
Action Check for air ow at coil, check coil fan connections, product may be
located too close to ovens, steam tables or fryers
E06
PCB board overheating
Action Check for air ow at back of unit, check air lter, verify heat sink fan is
operating, product may be located too close to ovens, steam tables or
fryers
E10
Communication error
Action check wiring between display and generator reset main power by
turning off unit and unplugging. Possible power problem due to loss of
phase or low voltage.
E25
Coil temperature sensor broken
Action Check coil temperature sensor connection
Only a qualied electrician should work on the activator.
Error Codes:
Displayed in the window.