Flash pattern Description
2 then 4
The Alarm.com module provisioning process could not
be completed. Power-cycle the system. If the error
persists, see Alarm.com CORE Technical Support.
2 then 5
The Alarm.com module provisioning process could not
be completed because the module is currently roaming
off the carrier’s primary network.
3
The Alarm.com module is trying to register on the cellular
network. If it persists for more than a few minutes, the
module is having problems registering. Check L4 for
signal level. If signal level is lower than 2 bars, change
the panel’s location or use a remote antenna option.
4
The Alarm.com module is registered on the cellular
network but could not connect with Alarm.com. If the
error persists, see Alarm.com CORE Technical Support.
5
The radio on the module is not working correctly. If this
persists for more than a few minutes, the module may
need to be replaced. This error is extremely rare, so
please verify that the module is flashing 5 times.
6
This indicates an error only if it persists for more than a
minute. Otherwise, it’s an indication that the module is
resolving an unusual condition regarding communication
with the cellular network.
7
The SEM is unable to access panel programming. Check
the panel wiring and installer code.
8
If this error persists, the account may have been set up
incorrectly. Check that the serial number being used
matches the serial number used to create the account. If
the serial numbers are the same, contact Alarm.com
CORE Technical Support.
Path LED
The Path LED flashes to indicate the active communication path (cellular, broadband, or both) to Alarm.com.