1. Verify the Vista panel version meets the minimum revision number required for this feature.
◦ Vista-10P rev 2.0+
◦ Vista-15P rev 3.1+
◦ Vista-20P rev 5.2+
◦ Vista-21iP rev 3.1+
2. Resync the installer code if a zone scan is not initiating upon power-up.
a. To resync the installer code, use the keypad to change the installer code to a new, unique code.
b. After resyncing the installer code, power cycle the panel and verify a zone scan is initiated.
3. Enter programming and execute *96 to reset the account number and initialize the downloader. Then exit
programming via *99, power cycle the system and verify the zone scan is initiated.
4. Verify the programming settings set during initialization are correct.
◦ Verify the Sub ID Primary *43 value is a four-digit value with no zeros (1111 or FFFF is recommended). The
SEM does not support zero values (e.g., 0000 or 1010) in
this section.
◦ Verify the Report Format Primary/Secondary *48 value is set to 7,7.
5. Power cycle the system and request the firmware version.
Questions?
If you are experiencing difficulties with your installation, please contact Alarm.com CORE Technical Support at
866-834-0470 and we'll be happy to assist further.
Specifications
Power requirements
13.6 V nominal, 125 mA nominal (continuous), 230 mA
maximum
Cellular network 4G LTE with 3G HSPA, 2G GSM fallback
Panel interfaces Two keypad BUS connections, 12 V power and ground
Alarm.com module indicators Five LEDs (red, yellow, or green)
SEM circuit board indicators Five LEDs (red, green, yellow, or blue)
Operating temperature 14 to 131°F (-10 to 55°C)
Storage temperature -30 to 140°F (-34 to 60°C)
Humidity 90% relative humidity non-condensing
Enclosure dimensions
(L x W x D) 7.66 x 4.35 x 1.65 in. (19.46 x 11.05 x 4.19
cm)