8212 DECT Handset
Maintenance Manual
8AL90334ENAAed01 8 /17
4. Clear counters
This function will clear all the counters in the sub menus: Power, network and OS. The log
counters (number of resets, New battery, Out of lock, etc.) can also be cleared separately in
each log menu.
The logs are described in the table below
These are debug error logs retrieved from the PP log file. The last log retrieved
is formatted into:
Error: Log event error code. Valid value is 0000 to FFFF (in Hex).
Line: Location within the software code which triggered this error. Valid value is
0000 to FFFF (in Hex).
Address: Register bank and/address from which error occurred. Valid value is
00000000 to FFFFFFFF (in Hex.)
Timestamp: Date and Time when the log error event occurred.
This reports of the function/exception handler that runs after an erroneous state
in handset operation.
Next assert ID: Immediate exception handler ID to be run when a specific error
occurs. Valid value is 00 to FF (in Hex).
Assert address: Register bank and/address where an exception handler is
executed as a result of the error which occurred. Valid value is 00000000 to
FFFFFFFF (in Hex.)