The  line contains the  list  of base stations identified by  the  handset as 
RPNs of the bases in respect to the signal strength values below. Up to 5 
RPNs can be displayed. 
This indicates the actual signal strength information (RSSI) to the base 
station the current handset is locked to and additional RFPs visible. RSSI 
unit  is  -dBm.  The  RSSI value  increases  the  closer  the  base  is  to  the 
handset. 
If the base could not be detected, the RSSI value will decrease and after 
a while the entry will be deleted, if e.g. the dummy-bearer position has 
changed or the RFP is unreachable. 
 
See  "survey_doc_DECT_AGAPdm09011b0280086533.pdf"  to  explain additional  lines  of  the  site 
survey. 
Note:  
- Long press on * key:   Slow/Rapid measurements 
- Long press on # key:   No Lock / Lock to base 
 
Note: 
This site survey mode is not appropriate for Dect installations due to lack of accuracy of quality 
index. 
 
For Dect installations, please refer to “DECT and IP-DECT Engineering Rules and Site Survey Kit 
Manual (8AL_90874_USAAed01)” 
 
HS Logs  
The  HS  log  is  a  debugging  feature  that  allows  the  user  to  retrieve  low  level  interesting 
messages from the handset.  
The logs is divided into 4 submenus 
 
1.  Power 
o  Number of resets. 
o  Number of new battery insertions 
 