8212 DECT Handset
Maintenance Manual
8AL90334ENAAed01 6 /17
Parameter/Line
Description
RPN
The line contains the list of base stations identified by the handset as
RPNs of the bases in respect to the signal strength values below. Up to 5
RPNs can be displayed.
-dBm
(Signal Strength)
This indicates the actual signal strength information (RSSI) to the base
station the current handset is locked to and additional RFPs visible. RSSI
unit is -dBm. The RSSI value increases the closer the base is to the
handset.
If the base could not be detected, the RSSI value will decrease and after
a while the entry will be deleted, if e.g. the dummy-bearer position has
changed or the RFP is unreachable.
See "survey_doc_DECT_AGAPdm09011b0280086533.pdf" to explain additional lines of the site
survey.
Note:
- Long press on * key: Slow/Rapid measurements
- Long press on # key: No Lock / Lock to base
Note:
This site survey mode is not appropriate for Dect installations due to lack of accuracy of quality
index.
For Dect installations, please refer to “DECT and IP-DECT Engineering Rules and Site Survey Kit
Manual (8AL_90874_USAAed01)”
HS Logs
The HS log is a debugging feature that allows the user to retrieve low level interesting
messages from the handset.
The logs is divided into 4 submenus
1. Power
o Number of resets.
o Number of new battery insertions
Screenshots

Other manuals for Alcatel-Lucent 8212

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Alcatel-Lucent 8212 and is the answer not in the manual?

Alcatel-Lucent 8212 Specifications

General IconGeneral
BrandAlcatel-Lucent
Model8212
CategoryIP Phone
LanguageEnglish

Related product manuals