8232 DECT Handset  
Maintenance Manual 
 
8AL 90305 USAA ed02                   6 /16 
 
See "survey_doc_DECT_AGAPdm09011b0280086533.pdf" to explain additional lines of the site survey. 
Note:  
- Long press on * key:   Slow/Rapid measurements 
- Long press on # key:   No Lock / Lock to base 
 
Note : 
This site survey mode is not appropriate for Dect installations due to lack of accuracy of quality index. 
 
For Dect installations, please refer to “DECT and IP-DECT Engineering Rules and Site Survey Kit Manual 
(8AL_90874_USAAed01)” 
 
HS Logs  
The HS log is a debugging feature that allows the user to retrieve low level interesting messages from 
the handset.  
 
Info: This information may be requested by Technical Support in case of site debugging 
 
These  are  debug  error  logs  retrieved  from  the  PP  log  file.  The  last  log 
retrieved is formatted into: 
Error: Log event error code. Valid value is 0000 to FFFF (in Hex). 
Line:  Location  within  the  software  code  which  triggered  this  error.  Valid 
value is 0000 to FFFF (in Hex). 
Address: Register bank and/address from which error occurred. Valid value is 
00000000 to FFFFFFFF (in Hex.) 
Timestamp: Date and Time when the log error event occurred. 
This reports  of  the  function/exception handler  that  runs  after  an  erroneous 
state in handset operation. 
Next  assert  ID:  Immediate  exception  handler  ID  to  be  run  when  a  specific 
error occurs. Valid value is 00 to FF (in Hex). 
Assert  address:  Register  bank  and/address  where  an  exception  handler  is 
executed as a result of the error which occurred. Valid value is 00000000 to 
FFFFFFFF (in Hex.) 
 
Screenshots