8232 DECT Handset
Maintenance Manual
8AL 90305 USAA ed02 7 /16
Status
This provides the present condition of the handset and the base station to which the handset is locked
to.
Some of the information available in this mode is described in the table below (this information is
updated during location request update from the DECT system).
Parameter
Description
SW Version
Software presently installed in the handset.
Nomenclature: Version Date Stamp
(for e.g.: 41.81 Branch: 0002
00.21 01-07-2010 00:00).
HW Version
Current hardware module used in the handset, V9R2 where V9 is the PCB
Version and R2 is the Schematic version
D: 1.2 is the display driver used in the phone
DECT Band
Operating frequency of system. DECT band includes US, EU, SA, N/A
options.
Battery Level
Current handset battery energy level (in %).
IPEI:
Unique identifier of the handset
RSSI:
Current Rssi level of the handset
Power Level:
Current power level of the handset
Frequency:
Operating frequency area of the handset
Mode:
This shows the current DECT mode the handset is configured to use.
The mode is automatically detected based on the carrier channel
and carrier offset and how it matches the actual carrier frequency.
There are 3 modes:
INT, OTHERS or Unknown
Free memory:
Number of bytes currently not used by the handset
INT: This is either EU_DECT or MALAYSIA_DECT
OTHERS: This is either US_DECT, SA_DECT, TAIWAN_DECT, CHINA_DECT, THAILAND_DECT
or BRAZIL_DECT
Unknown: UNKNOWN_DECT_MODE