AOS Release 6.4.6.R01 Release Notes November 2013
Auto-Upgrading - Step 2. Upgrade Uboot/Miniboot and AOS
Follow the steps below to upgrade the Uboot/Miniboot and AOS. This step will upgrade both
Uboot/Miniboot and AOS once the switch or stack is rebooted. Note the following:
The CMMs must be certified and synchronized and running from Working directory.
This procedure will require a reboot of the switch or stack.
Make sure the destination paths are correct when transferring the files. Also, when the
transfer is complete, verify the file sizes are the same as the original indicating a
successful binary transfer.
1. Download and extract the 6.4.6.R01 Upgrade archive from the Service & Support website. The
archive will contain the files to be used for the upgrade.
FPGA/CPLD Files
Uboot/Miniboot Files (if required)
AOS Files (required)
2. FTP (Binary) the Uboot/Miniboot and FPGA/CPLD files listed above to the /flash directory on the
primary CMM.
3. FTP (Binary) the image files listed above to the /flash/working directory on the primary CMM.
4. Execute the following CLI command to update the Uboot/Miniboot on the switch(es) (can be a
standalone or stack).
-> update uboot all
-> update miniboot all
If connected via a console connection update messages will be displayed providing the status of
the update.
If connected remotely update messages will not be displayed. After approximately 10 seconds
issue the ‘show ni’ command, when the update is complete the UBOOT-Miniboot Version will
display the upgraded version.
WARNING: DO NOT INTERRUPT the upgrade process until it is complete. Interruption of the
process will result in an unrecoverable failure condition.
5. Reboot the switch. This will update both the Uboot/Miniboot and AOS.
-> reload working no rollback-timeout