Alcatel-Lucent OS6560-P48X4 - Setting Port Priority Levels; Setting the Capacitor Detection Method; Understanding Guard Band

Alcatel-Lucent OS6560-P48X4
102 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Understanding Guard Band Managing Power over Ethernet (PoE)
page 4-8 OmniSwitch 6560 Hardware Users Guide December 2019
Note. Changing the maximum power available to a slot or port does not reserve or immediately allocate
that power. These settings are only used for configuring a maximum amount of power that may be used,
any unused power is still available and remains a part of the overall PoE budget.
Setting Port Priority Levels
As not all Powered Devices (PDs) connected to the switch have the same priority within a network setting,
the OmniSwitch allows the administrator to specify priority levels on a port-by-port basis. Priority levels
include low, high, and critical. The default priority level for a port is low.
Low. This default value is used for port(s) that have low-priority devices attached. In the event of a
power management issue, inline power to low-priority is interrupted first (i.e., before critical and high-
priority).
High. This value is used for port(s) that have important, but not mission-critical, devices attached. If
other ports in the chassis have been configured as critical, inline power to high-priority is given second
priority.
Critical. This value is used for port(s) that have mission-critical devices attached, and therefore require
top (i.e., critical) priority. In the event of a power management issue, inline power to critical is main-
tained as long as possible.
To change the priority level for a particular port, use the lanpower priority command. Since the switch
allows you to set priority levels on a port-by-port basis, be sure to specify chassis/slot/port information in
the command line. For example, the syntax
-> lanpower port 1/1/6 priority critical
changes the priority value of port 6 to the highest priority level of critical. Now that the default value has
been reconfigured, this port should be reserved for those PDs that are mission critical for network opera-
tions.
Setting the Capacitor Detection Method
By default, the capacitor detection method is disabled. To enable it, use the lanpower capacitor-detec-
tion. For example:
-> lanpower slot 3/1 capacitor-detection enable
Note. The capacitive detection method should only be enabled to support legacy IP phones. This feature
is not compatible with IEEE specifications. Please contact your Alcatel-Lucent sales engineer or Customer
Support representative to find out which Alcatel-Lucent IP phones models need capacitive
detection enabled.
Understanding Guard Band
Guard Band functionality is implemented when the switch has to provide power to a newly connected PD. This
functionality is more relevant on switches that have a lower amount of total PoE power available for the switch
but a higher default maximum PoE power available to some ports.