Maintenance
Replacing the engraver tip
Change the engraving tip as soon as it becomes worn and no longer
delivers the desired engraving results.
WARNING! Disconnect the engraver from the power supply before
making any adjustments or undertaking maintenance procedures.
1) Remove the protection cap (a) from the engraver tip (1). (Fig. A1)
2) Loosen the tip release cap (2) by turning it anti-clockwise and then
remove it from the engraver. (Fig. C1)
3) Remove the spring and washer from the engraver tip and then remove
the engraver tip (1). (Fig. C2, C3)
4) To t the new engraving tip (not supplied), slide the washer and spring
onto a new engraving tip rstly. Then insert the new tip through the
centre of the hole of the engraver, ensuring the tip fully enters the
housing.
3) Tighten the tip release cap (2) fully by rotating it in a clockwise
direction.