English Maintenance
14 Plate Heat Exchanger
EN
EN
Regasketing
Open the plate heat exchanger according
to page 8, and remove the plate that is to
have a new gasket.
Remove the old gasket.
Assure that all sealing surfaces are dry,
clean and free of foreign matter.
Attach the clip-on gasket to the plate. Slip
the gasket prongs under the edge of the
plate.
Proceed with the next plate to be regasket-
ed until all plates in need of regasketing
are done with.
Close the plate heat exchanger according
to page 12.
Glued gaskets
Separate gluing instructions will be delivered togeth-
er with the glue.
1
2
3
4
Note!
Make sure the two gasket prongs are in
correct position.