Maintenance English
Plate Heat Exchanger 7
EN
EN
Maintenance
Cleaning-In-Place (CIP)
The Cleaning-In-Place (CIP) equipment permits
cleaning of the plate heat exchanger without opening
it.
If CIP cannot be done, cleaning must be performed
manually, see section “Manual cleaning”.
CIP performs
cleaning of fouling and descaling of lime deposits
passivation of cleaned surfaces to reduce sus-
ceptibility to corrosion
neutralization of cleaning liquids before draining.
Follow the instructions of the CIP equipment.
CIP equipment
CIP model
Maximum number of plates
M3 M6 M6-M M10-B M10-M TS6-M
CIP 20 90 89 62 40 27 56
CIP 40 178 124 81 53 110
Cleaning liquids
Cleaning liquid Description
AlfaCaus A strong alkaline liquid, for removing paint, fat, oil
and biological deposits.
AlfaPhos An acid cleaning liquid for removing metallic oxides,
rust, lime and other inorganic scale.
AlfaPass An alkaline liquid for passivation (inhibition of corro-
sion).
AlfaNeutra A strong alkaline liquid for neutralization of AlfaCar-
bon or AlfaPhos before drainage.

Other manuals for Alfa Laval T5

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Alfa Laval T5 and is the answer not in the manual?

Alfa Laval T5 Specifications

General IconGeneral
BrandAlfa Laval
ModelT5
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals