- Protective plate B and upper plate A on the joint are stuck with silicon on both left and right sides so
that they cannot fall out of place during transportation. When the stove is lit for the first time, the silicon burns
thus enabling the removal of the plates and cleaning of the space behind plate B.
Always ensure that the stove and ash are completely cool.
This is a firebox (box-shaped) where wood mass pellets burn. See Figure 14. It is recommended that the firebox
should be cleaned with a vacuum cleaner after each use (when the stove is cool). After every third use, it is
recommended that the firebox should be taken out for ensuring that there is no excessive ash accumulated at the
bottom of the firebox. Then place the firebox back in its place, making it stable, to ensure the safe operation of the
stove.
If you have any doubts, please do not hesitate to call the authorized service centre for further information and
clarification, as the manufacturer does not have any insight into the installation of the stove and does not offer any
warranty for the incorporation of the stove and its maintenance.
The manufacturer shall not be liable for any damages caused by third parties.
ASH TRAY (if it is full, it should be vacuumed or emptied):
The stove and ash must be completely cool.
The ash tray must be cleaned once a week, by vacuuming or emptying it. In this way, all the impurities left after the
combustion of pellets will be removed. Then the ash tray must be properly placed back.
− Unburned pellets must never be put into the ash box or tray.
− Clean the glass with a soft cloth.
DOOR WITH GLASS (the door should be checked and cleaned from time to time):
The stove and ash must be completely cool.
The glass is made of high temperature resistant pyroceramics. If any damage is caused to the glass, replace the glass
as soon as possible before you use the stove again. The glass must be replaced only by an authorized person.
6.2 CLEANING and MAINTENANCE (for maintenance workers)
− THE FLUE CHANNELS – CHIMNEY (these should be cleaned every six months or after burning two tons of pellets)
The stove and ash must be completely cool.
This wind resistant flue channel (chimney) must be checked and cleaned each year. This should preferably be done at
the beginning of the heating season. For the professional cleaning of these elements of the stove system you should
preferably contact authorized professionals. The spots that should be paid special attention to during cleaning and that
should be cleaned particularly well are shown in Figure 15.
− INNER FIREBOX (every two weeks)
The stove and ash must be completely cool.
For proper cleaning, remove ash from behind the cast plate every two or three weeks, using a vacuum cleaner and
turning or removing the plate as shown under item 6.1 (Figures 11, 12 and 13).
− THE EXHAUST SPACE OF THE SMOKE FAN (it should be checked and cleaned every six months)
The stove and ash must be completely cool.
To clean the inner space for smoke discharge, first remove the cover i.e. plug at the bottom of the ash box casing and
insert the vacuum cleaner hose through this opening, so that you may vacuum any residual ash and ensure the proper
operation of the stove, Figure 16.
− GENERAL CLEANING AT THE END OF THE HEATING SEASON
The stove and ash must be completely cool – unplug the power cable of the stove.
1. Hole for entering a heating
element to ignite the fuel