9
For the proper and safe installation of the ventilation grid, see the data in Table 4. These are minimum distances form
any air space or smoke discharge. This value can change the configuration of air pressure. These distances should
correspond to the sequence in order to ensure, for example, that an open window intakes external air, taking it away
from the stove itself.
The ventilation grid must be installed at least
1 m under the door, window, flue pipe, air chambers, etc.
1 m horizontally from
0.3 m above
2 m away from smoke outlet
Table 4: Minimum distances for the intakes of combustion air
3.5 CONNECTION TO THE ELECTRIC POWER SUPPLY
These stoves should be connected to the electric power supply. Our stoves have electric cables suitable for medium
temperatures. If the cable should be replaced (e.g. because it is damaged), please consult our authorized technical
personnel, our experts. Before you connect the stove to the electric power supply, ensure that:
The characteristics of the electric system correspond to the data i.e. specification stated on the nameplate of the
stove.
-The smoke discharge system, if it is metal, must have an operational grounding connection in accordance with
applicable standards and legal regulations. Grounding is prescribed by the law.
The electric cable must never reach a temperature which is by 80
0
C higher than the ambient temperature. If you
want to
obtain a direct connection to voltage, you should install a bipolar switch with a minimum clearance of 3 mm between
the
contacts, with the dimensions for electric load shown in the nameplate, and in accordance with applicable standards.
Yellow-green grounding cables must not be switched off by the switch. When the stove is installed at its place, the
bipolar switch or the socket must be easily accessible.
If the stove will not be used for a longer period, switch it off from the power supply or turn the switch into a switched
off
(0) position. In the case of any breakdown or improper operation, switch the stove off immediately or turn the switch
into
the switched off position (0) and contact the authorized service centre.
4.0 IMPORTANT INSTRUCTIONS
THESE ARE IMPORTANT OBLIGATORY INSTRUCTIONS FOR THE SAFETY OF PEOPLE, ANIMALS AND
PROPERTY.
We would like to inform the stove installer on some general instructions that he must adhere to in order to install the
stove properly. These standards are required, but not fully. For further and more precise information, read the
remaining part of this Manual.
− Connect the stove to a grounded socket. Figure 9
− Put the switch on the back of the stove in position 1. Figure 10
− Do not allow children and pets to come near the stove.
− Use only biofuel pellets, and not any other types of fuel.
− Inform all the users on possible risks and dangers and teach them how to handle the device.
− If the stove is installed on a wooden floor, it is recommendable to insulate its stand.
The stove functions with a negative pressure combustion chamber. Because of that, ensure that the flue pipe is
thermally sealed i.e. insulated.
When the stove is lit for the first time, a smaller quantity of paint (not harmful to health) covering the stove will
evaporate because of the painting process stabilization. Ventilate the room in order to remove these vapours
from it.
Figure 9 Figure 10
Thermostat 180ºC
Thermostat 80ºC
Main switch