temperature of the funnel for pellet inlet is too high, and in this case the following message appears " ALAr dEP no ".
This is one additional safety mechanical device. In order to return to normal operation, you need to wait for the stove to
get’ cold (the fans for smoke and for cooling are in function). This cooling lasts about twenty minutes. Than restore the
function of the safety thermostat that has blocked the stove operation (by unscrewing the plastic cover and manually
press the thermostat button until a silent metal sound is heard) which is located in the lower back part, above the main
switch (0-1) Figure 10 and then press the button 4 in a duration of 3 seconds until the stove returns back to it ON
(switched on) position. The upper thermostat blocks the stove operation when the stove chamber heats at 180°C and
the lower one when the case of snail transmission heats at 80°C.
NOTE: If one of these two last alarms is active, make sure that the chamber is not clogged with ash and that the
flue is not partially clogged.
Figure 27
9.4.6. Alarm for failed ignition
It triggers when the ignition stage failed and the following message appears „ALAr Acc no“ (Figure 28). The switching
off procedure immediately activates.
Figure 28
9.4.7. Alarm for power outage
When the stove is switched on, a power outage stops the operation of the electrical devices on the stove. When the
power supply returns, an alarm signalization occurs as shown in figure 29:
Figure 29
9.4.8. Alarm ALAr Fan (alarm for discharge fan)
If the smoke discharge fan does not function well, an alarm occurs – ALAr FAn FaiL (Figure 30).
The stove begins the procedure of switching off while the alarm is on.
Figure 30
9.4.9. ,,StoP FirE“ (it is not an alarm)
StoP FirEmode can be activated in adjusted intervals, during normal operation. Cleaning of the stove is performed.
A message „StoP FirE“ is shown (Figure 31).
Figure 31
By pressing the button 4 you can delete, that is, remove a message from the display. The alarm signals are followed
by a sound signal.
dEP
Acc no
no rEtE
FAn FAiL