ELECTRIC DRIVEN COLD
WATER CLEANERS
DAILY
EACH
HR
FIRST
8 HRS
AFTER
FIRST
50
HRS
EVERY
50
HRS
EVERY
100
HRS
EVERY
500
HRS
YEARLY
OIL BATH WATER PUMP:
Oil Level check and add as needed per
PUMP SERVICE insert.
Oil Change – drain and refill per PUMP
SERVICE insert. CAUTION: Used oil must
be disposed into an environment safe
container and brought to an oil recycling
center.
Oil Contamination – Milky color indicates
water
HOSES:
Blistering, Loose Covering
Abrasion of cover exposing
reinforcement.
Cuts exposing reinforcement
BELTS:
Cracks or fraying
Belt Tension - For correct belt tension,
see MACHINE MAINTENANCE insert.
SPRAY TIP:
Check Tip for debris.
PUMP MOTORS WITH GREASE
FITTINGS:
Remove Drain Plug. Use 1 or 2 full
strokes of Shell "DOLIUM R", Chevron
"SR1 No. 2" or Texaco "PREMIUM RB".
operate 20 minutes and replace drain
plug.
SCREEN—WATER:
Check Inlet Hose Screen for debris .
Check Float Tank Hose Screen (if so
equipped)for debris .
Check Water Filter (if so equipped)for debris
see breakdown elsewhere in this manual.
GUARDS AND SHIELDS:
Check That All Guards and shields are in
place and secure.
FREEZING TEMPERATURES:
Freezing Temperatures Break water pumps
and like components. See STORAGE tn the
MACHINE MAINTENACE section for cold
weather instructions.