20 Rockwell Automation Publication 1606-RM055A-EN-P - December 2016
Basic Power Supply 5 A
Environment
Attribute 1606-XLB120E Notes
Operational temperature
(1)
-10… +70 °C (14… 158 °F) reduce output power according to Figure 22
Storage temperature -40… +85 °C (-40… 185 °F) for storage and transportation
Output derating
(2)
3W/°C (55…70 °C 131…158 °F)
3W/°C (50…70 °C; 122…158 °F)
for AC 110-120/220-240V mains systems
for AC 100/200V mains systems
Humidity
(3)
5...95% r.h. IEC 60068-2-30
Vibration sinusoidal
(4)
2-17.8Hz: ±1.6mm; 17.8-500Hz: 2g
2 hours/axis
IEC 60068-2-6
Shock
(5)
30g 6ms, 20g 11ms
3 bumps/direction, 18 bumps in total
IEC 60068-2-27
Altitude 0…2000 m (0…6 560 ft.) without any restrictions
2000…6000m (6 560… 20 000 ft) reduce output power or ambient temperature,
see Figure 22 IEC 62103, EN 50178,
overvoltage category II
Altitude derating 7.5W/1000m or 5 °C/1000m > 2000 m (6500 ft.), see Figure 23
Overvoltage category III IEC 62103, EN 50178, altitudes up to 2000m
II altitudes from 2000m to 6000m
Degree of pollution 2 IEC 62103, EN 50178, not conductive
LABS compatibility The unit does not release any silicone or other LABS-critical substances and is suitable for
use in paint shops.
(1) Operational temperature is the same as the ambient or surrounding temperature and is defined as the air temperature 2cm below
the unit.
(2) For AC 208V mains use AC 200…220V values.
(3) Do not energize while condensation is present.
(4) Tested on a DIN Rail with a thickness of 1.3 mm.
(5) Tested on a DIN Rail with a thickness of 1.3 mm.
Figure 22 - Output Current vs. Ambient Temperature Figure 23 - Output Current vs. Altitude
0
-10 0 +20 +40
+70°C
1.0A
2.0A
4.0A
5.0A
+55
Allowable Output Current at 24V
3.1A
2.5A
Ambient Temperature
+50
a) AC 110-120/ 220-240V mains
b) AC 100/ 200V mains
a
b
Allowed Output
Current at 24V
0
0 2000 4000
6000m
1
2
3
4
5
6A
Altitude
A
.
.
.
T
a
m
b
<
5
5
°
C
B
.
.
.
T
a
m
b
<
4
5
°
C
C
.
.
.
T
a
m
b
<
3
5
°
C
A
B
C