Configuration Reference Information
The modules have these parameter groups: general parameters, safety input,
test output, safety output.
Parameter Groups
See Table 67Table 70 for the settings in each parameter group. All
parameters are set by using the Studio 5000 Logix Designer® application.
Table 67 - General Parameters
Parameter Name Value Description Default
Safety Output Error Latch Time 0…65,530 ms
(in increments of 10 ms)
Safety output errors are latched for this time. 1000 ms
Safety Input Error Latch Time 0…65,530 ms
(in increments of 10 ms)
Safety input or test output errors are latched for this time. 1000 ms
Table 68 - Safety Input Parameters
Parameter Name Value Description
Input Point Operation Type Single Channel Use as single channel.
Dual-channel Equivalent Use as dual-channel. Normal when both channels are ON or OFF.
Dual-channel Complementary Use as dual-channel. Normal when one channel is ON and the other channel is OFF.
Input Point Mode Not Used External input device is not connected.
Safety Test Pulse Use with a contact output device and in combination with a test output. By using this setting, short circuits
between input signal lines and the power supply (positive side) and short circuits between input signal lines
can be detected.
Safety A solid-state output safety sensor is connected.
Standard A standard device, such as a reset switch, is connected.
Safety Input Test Source Not Used The test output that is used with the input.
n is dependent on the module catalog number.
Test Output 0 to n
Input Delay Time
Off -> On
0…126 ms
(in increments of 6 ms)
Filter time for OFF to ON transition
Input Delay Time
On -> Off
0…126 ms
(in increments of 6 ms)
Filter time for ON to OFF transition
IMPORTANT When configuring a test output for Pulse Test mode, verify that the
corresponding safety input is configured for safety pulse test.