Point Guard I/O Safety Modules
Catalog Numbers 1734-IB8S, 1734-OB8S, 1734-IE4S, 1734-OBV2S
User Manual
Original Instructions

Table of Contents

Other manuals for Allen-Bradley 1734-IB8S

Question and Answer IconNeed help?

Do you have a question about the Allen-Bradley 1734-IB8S and is the answer not in the manual?

Allen-Bradley 1734-IB8S Specifications

General IconGeneral
ManufacturerAllen-Bradley
Product TypeDigital Input Module
SeriesPOINT I/O
Number of Inputs8
Input Voltage Category24V DC
Input Delay1 ms
Isolation Voltage50V continuous
Module LocationPOINT I/O system
Operating Temperature-20 to 60°C (-4 to 140°F)
Connection TypeRemovable terminal block
CompatibilityPOINT I/O system

Summary

Chapter 1 POINT Guard I/O Overview

Understand Suitability for Use

Guidelines for determining if the POINT Guard I/O modules are suitable for your application and system.

Safety Precautions

Essential safety measures and warnings for proper installation and operation of POINT Guard I/O modules.

Safety Application Requirements

Requirements for safety applications, including performance levels and safety integrity levels for POINT Guard I/O modules.

Chapter 4 Install the Module

Precautions

General precautions for use, including environmental, electrical safety, and ESD considerations.

Chapter 5 Configure the Module in a GuardLogix Controller System

Set up the Module

Initial steps for setting up POINT Guard I/O modules using the Logix Designer application.

Add and Configure Safety Digital Input Modules

Guide to adding and configuring safety digital input modules in the project.

Chapter 7 Configuring Safety Connections between a GuardLogix Controller and POINT Guard I/O Modules on a DeviceNet Network

Configure the Module in RSNetWorx for DeviceNet Software

Tasks required in RSNetWorx for DeviceNet before adding modules to a GuardLogix project.

Add the POINT Guard I/O Module to the Controller Project

Steps to add the POINT Guard I/O module to the controller project using Logix Designer.

Complete the Safety Configuration

Procedure to copy configuration signatures and safety network numbers between RSNetWorx and Logix Designer.

Chapter 8 Replacing POINT Guard I/O Modules

Replace a Module in a GuardLogix System on an EtherNet/IP Network

Guide for replacing modules in GuardLogix systems over EtherNet/IP, including configuration options.

Appendix C Specifications

Safety Digital Input Module Specifications

Specific safety input parameters for the 1734-IB8S Series A module.

Safety Digital Output Module Specifications

Specific safety output parameters for the 1734-OB8S Series B module.

Appendix D Safety Data

Product Failure Rates (failures per hour)

Table listing calculated product failure rates (PFD, PFH, STR, MTTF) for various configurations.

Appendix E Configuration Parameters

Table 22 Safety Digital Input Parameters

List of configurable parameters for safety digital inputs in Logix Designer.

Table 24 Safety Digital Output Parameters

List of configurable parameters for safety digital outputs in Logix Designer.

Table 25 Safety Analog Input Parameters

List of configurable parameters for safety analog inputs in Logix Designer.

Related product manuals