5–54 RIO Block Transfer
Publication
17476.6 - July 1996
Rung 2:11
MOVE THE VIRTUAL BTW CONTROL WORD TO THE M0 FILE FOR THE SN MODULE WHILE A BTR
IS IN PROGRESS, AND CONTINUE DOING SO UNTIL THE ENABLE, DONE AND ERROR BITS
ARE ALL TURNED OFF, COMPLETING THE HAND–SHAKE PROCESS.
| |
| |
| VIRTUAL BTW |
| BTW ENABLE CONTROL |
| BIT WORD |
| N7:53 +MOV–––––––––––––––+ |
|–+––––] [–––––+––––––––––––––––––––––––––––––––––––––––––+MOVE +–|
| | 15 | |Source N7:53| |
| | | | 0| |
| | | |Dest M0:1.200| |
| | | | *| |
| | | +––––––––––––––––––+ |
| | | |
| | | |
| | VIRTUAL | |
| | BTW DONE | |
| | BIT | |
| | N7:64 | |
| +––––] [–––––+ |
| | 13 | |
| | | |
| | | |
| | VIRTUAL | |
| | BTW ERROR | |
| | BIT | |
| | N7:64 | |
| +––––] [–––––+ |
| 12 |
Rung 2:12
| |
|–––––––––––––––––––––––––––––––––––––+END+––––––––––––––––––––––––––––––––––––|
| |