Battery Removal
The 400 and 600 terminals contain a lithium battery that is permanently connected and
should be removed only by trained professionals.
Follow these steps to remove the battery on the 400 and 600 terminals.
1. Disconnect power from the terminal.
2. Place the terminal, display side down, on a flat stable surface.
3. Detach the communication module, if attached, from the logic module by removing
the three screws.
4. Unlatch the eight retaining tabs (two on each side) on the back cover and remove
cover.
5. Locate the yellow battery on the logic board.
6. Remove the battery.
This product contains a hermetically sealed lithium battery which may need to be
replaced during the life of the product.
At the end of its life, the battery contained in this product should be collected separately
from any unsorted municipal waste.
The collectioin and recyling of batteries helps protect the environment and contributes to
the conservation of natural resources as valuable materials are recovered.
Retaining tabs
Battery
AB Parts

Other manuals for Allen-Bradley PanelView Plus 600

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allen-Bradley PanelView Plus 600 and is the answer not in the manual?

Allen-Bradley PanelView Plus 600 Specifications

General IconGeneral
Resolution320 x 240 pixels
TouchscreenAnalog resistive
BacklightLED
Operating SystemWindows CE
Power Supply24V DC
Communication PortsEthernet, RS-232
Memory64 MB RAM
Operating Temperature0°C to 50°C
Enclosure RatingNEMA 4X
ProcessorXScale processor