EasyManua.ls Logo

Allen-Bradley PanelView Plus 6

Allen-Bradley PanelView Plus 6
188 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
PanelView Plus 6 Terminals
Catalog Numbers 2711P-K4M5A8, 2711P-K4M5D8, 2711P-K4M20A8, 2711P-K4M20D8, 2711P-K4C5A8, 2711P-B4C5A8, 2711P-K4C5D8,
2711P-B4C5D8, 2711P-K4C20A8, 2711P-B4C20A8, 2711P-K4C20D8, 2711P-B4C20D8, 2711P-K6M5A8, 2711P-T6M5A8, 2711P-B6M5A8,
2711P-K6M5D8, 2711P-T6M5D8, 2711P-B6M5D8, 2711P-K6M20A8, 2711P-T6M20A8, 2711P-B6M20A8, 2711P-K6M20D8, 2711P-T6M20D8,
2711P-B6M20D8, 2711P-K6C5A8, 2711P-T6C5A8, 2711P-B6C5A8, 2711P-K6C5D8, 2711P-T6C5D8, 2711P-B6C5D8, 2711P-K6C20A8,
2711P-T6C20A8, 2711P-B6C20A8, 2711P-K6C20D8, 2711P-T6C20D8, 2711P-B6C20D8, 2711P-K6C5A9, 2711P-T6C5A9, 2711P-B6C5A9,
2711P-K6C5D9, 2711P-T6C5D9, 2711P-B6C5D9, 2711P-K6C20A9, 2711P-T6C20A9, 2711P-B6C20A9, 2711P-K6C20D9, 2711P-T6C20D9,
2711P-B6C20D9, 2711P-K7C4D8, 2711P-T7C4D8, 2711P-B7C4D8, 2711P-T7C4D8K, 2711P-K7C4A8, 2711P-T7C4A8, 2711P-B7C4A8,
2711P-K10C4D8, 2711P-T10C4D8, 2711P-B10C4D8, 2711P-K10C4A8, 2711P-T10C4A8, 2711P-B10C4A8, 2711P-K12C4D8, 2711P-T12C4D8,
2711P-B12C4D8, 2711P-T12C4D8K, 2711P-K12C4A8, 2711P-T12C4A8, 2711P-B12C4A8, 2711P-K15C4D8, 2711P-T15C4D8, 2711P-B15C4D8,
2711P-K15C4A8, 2711P-T15C4A8, 2711P-B15C4A8, 2711P-K7C4D9, 2711P-T7C4D9, 2711P-B7C4D9, 2711P-K7C4A9, 2711P-T7C4A9,
2711P-B7C4A9, 2711P-K10C4D9, 2711P-T10C4D9, 2711P-B10C4D9, 2711P-K10C4A9, 2711P-T10C4A9, 2711P-B10C4A9, 2711P-K12C4D9,
2711P-T12C4D9, 2711P-B12C4D9, 2711P-K12C4A9, 2711P-T12C4A9, 2711P-B12C4A9, 2711P-K15C4D9, 2711P-T15C4D9, 2711P-B15C4D9,
2711P-K15C4A9, 2711P-T15C4A9, 2711P-B15C4A9
User Manual
Original Instructions

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Allen-Bradley PanelView Plus 6 and is the answer not in the manual?

Allen-Bradley PanelView Plus 6 Specifications

General IconGeneral
Display TypeTFT LCD
Operating SystemWindows CE
Power Supply24V DC
Resolution640 x 480 pixels
Communication PortsEthernet, USB, Serial
Operating Temperature0°C to 50°C
Enclosure RatingIP65
TouchscreenAnalog Resistive

Summary

Preface

Firmware Upgrades

Information on obtaining and installing the latest firmware for PanelView Plus 6 terminals.

Chapter 1 Overview

400 and 600 Terminal Features

Describes the communication options and physical components of PanelView Plus 6 - 400 and 600 terminals.

700 to 1500 Terminal Features

Details the modular components and features of PanelView Plus 6 - 700 to 1500 terminals.

400600 Terminal Selections

Provides a breakdown of catalog numbers for PanelView Plus 6 - 400 and 600 terminals.

700 to 1500 Terminal Selections

Details catalog number breakdown for PanelView Plus 6 - 700 to 1500 terminals.

Chapter 2 Install Terminal

Mount the 400600 Terminal in a Panel

Step-by-step instructions for securely mounting PanelView Plus 6 - 400 and 600 terminals into a panel using mounting levers.

Mount the 700 to 1500 Terminal in a Panel

Instructions for installing PanelView Plus 6 - 700 to 1500 terminals into a panel using mounting clips.

Remove and Install the Power Terminal Block

Procedures for removing and replacing the power terminal block on PanelView Plus 6 terminals.

DC Power Connections

Details on connecting DC power to PanelView Plus 6 terminals, including power ratings and safety precautions.

AC Power Connections

Explains how to connect AC power to PanelView Plus 6 terminals, including protective and functional earth connections.

Reset the Terminal

Provides methods for restarting the terminal without removing power, using reset switches or software options.

Chapter 3 Configuration Mode

Access Configuration Mode

Explains how to enter the terminal's configuration mode for settings and application management.

Terminal Settings

Covers various terminal settings not specific to applications, such as display, network, and input devices.

Load and Run Application

Instructions for loading and executing .mer applications from storage devices onto the terminal.

Start-up Options

Details how to configure the terminal's action on startup: launch HMI, configuration mode, or desktop.

Enable Desktop Access

Step-by-step guide to enabling access to the Windows desktop, including password setup.

Disable Desktop Access

Procedure for restricting access to the Windows desktop, requiring password and challenge question.

Set a Desktop Password

Instructions for setting a password and challenge question for desktop access management.

Reset the Desktop Password

Guide to clearing and resetting the desktop access password and challenge question.

Chapter 4 Windows CE Operating System

Backup and Restore

Procedures for backing up and restoring the terminal's system image, including configuration data.

Chapter 5 Install and Replace Components

Install or Replace the Logic Module

Step-by-step instructions for installing or replacing the logic module on PanelView Plus 6 terminals.

Install or Replace a Communication Module

Procedures for installing or replacing communication modules on PanelView Plus 6 terminals.

Replace the Display Module

Instructions for removing and replacing the display module on PanelView Plus 6 terminals.

Replace the Battery

Procedures for replacing the real-time clock lithium battery in PanelView Plus 6 terminals.

Chapter 6 Terminal Connections

Ethernet Connections

Covers connecting the terminal to an EtherNet/IP network using standard Ethernet connections.

Controller Connections

Summarizes PanelView Plus 6 terminal connections to various SLC, PLC-5, MicroLogix, and Logix controllers.

Chapter 7 Firmware Upgrades

Firmware Upgrade Wizard

Details on using the wizard to upgrade terminal firmware via storage device or network.

Upgrade Terminal Firmware from a Storage Device

Step-by-step process for creating and using a firmware upgrade card from a USB drive or SD card.

Upgrade Terminal Firmware over the Network

Procedure for upgrading terminal firmware directly from a computer over a network connection.

Chapter 8 Troubleshooting

Terminal Does Not Start Properly

Provides troubleshooting steps for issues related to the terminal failing to start, including power and indicator checks.

Access Maintenance Operations

Steps to access maintenance mode for diagnostics and repairs, including Safe mode and terminal reset.

Restore Factory Defaults

Procedure to restore the terminal to its original factory default state, typically after a failed firmware upgrade.

Related product manuals