Rockwell Automation Publication 2711P-UM006E-EN-P - January 2017 153
Terminal Connections Chapter 6
Controller Connections
The tables provide a summary of PanelView Plus 6 connections to controllers
and interface modules for runtime communication.
Table 74 - PanelView Plus 6 Terminals to SLC Controllers
Protocol PanelView Plus 6 Comm Port
SLC 500, 5/01, 5/02
CH1 RJ45
(DH-485)
SLC 5/03, 5/04, 5/05
CH0 (9-pin RS-232)
(DF1 or DH-485)
SLC 5/03
CH1 (RJ45)
(DH-485)
SLC 5/04
CH1 (DH+)
SLC 5/05
CH1 (ENET)
DF1
RS-232 (DF1) port (9-pin)
All terminals
2711-NC13 (5 m/16 ft)
2711-NC14 (10 m/32 ft)
——
DH-485
RS-232 (DH-485) port (9-pin)
All terminals
Use AIC+ module
(1761-NET-AIC) to connect to
port 1 or 2
2711-NC13 (5 m/16 ft)
2711-NC14 (10 m/32 ft)
Use AIC+ module
(1761-NET-AIC) to
connect to port 1 or 2
——
DH-485 port
700 to 1500 terminals only
Require 2711P-RN6, 2711P-RN6K
1761-CBL-AS03
(3 m/10 ft)
1761-CBL-AS09
(9 m/30 ft)
Use AIC+ module
(1761-NET-AIC)
to connect to port 3
1761-CBL-AS03
(3 m/10 ft)
1761-CBL-AS09
(9 m/30 ft)
——
EtherNet/IP
EtherNet/IP port
All terminals
2711P-RN20 provides additional port - 700 to
1500 terminals only
Use 1761-NET-ENI module
with Ethernet cable
——
1585J-M type cable or
2711P-CBL-EX04
(4 m/14 ft)
ControlNet ControlNet port
700 to 1500 terminals only
Require 2711P-RN15S, 2711P-RN15SK
——
DH+
DH+ port
700 to 1500 terminals only
Require 2711P-RN6, 2711P-RN6K
——
Shielded
twinaxial
cable (1770-CD)
Table 75 - PanelView Plus 6 Terminals to PLC-5 and MicroLogix Controllers
Protocol PanelView Plus 6 Comm Port
PLC-5, PLC-5C, PLC-5E
CH0 (25-pin RS-232)
(DF1)
MicroLogix 1400, 1500LRP
CH1/CH2 (9-pin RS-232)
(DF1 or DH-485)
MicroLogix 1000, 1100, 1200,
1400, 1500LSP
CH0 (8-pin Mini DIN)
(DF1 or DH-485)
MicroLogix 1100, 1400
Ethernet
DF1
RS-232 (DF1) port (9-pin)
All terminals
2711-NC13 (5 m/16 ft)
2711-NC14 (10 m/32 ft)
(9-to-25 pin adapter required)
2711-NC13 (5 m/16 ft)
2711-NC14 (10 m/32 ft)
2711-NC21 (5 m/16 ft)
2711-NC22 (15 m/49 ft)
(1)
DH-485
RS-232 (DH-485) port (9-pin)
All terminals
2711-NC13 (5 m/16 ft)
2711-NC14 (10 m/32 ft)
2711-NC21 (5 m/16 ft)
2711-NC22 (15 m/49 ft)
DH-485 port
700 to 1500 terminals only
Require 2711P-RN6, 2711P-RN6K
Use AIC+ module
(1761-NET-AIC)
to connect to port 3
EtherNet/IP
EtherNet/IP port
All terminals
2711P-RN20 provides additional port - 700
to 1500 terminals only
To PLC-5E with
1585J-M type cable or
2711P- CBL-EX04 (4 m/14 ft)
Use 1761-NET-ENI module
with Ethernet cable
1585J-M type cable or
2711P- CBL-EX04 (4 m/14 ft)
(1)
ControlNet
ControlNet port
700 to 1500 terminals only
Require 2711P-RN15S, 2711P-RN15SK
To PLC-5C with
ControlNet cable
——
DH+
DH+ port
700 to 1500 terminals only
Require 2711P-RN6, 2711P-RN6K
Shielded twinaxial cable
(1770-CD)
——
(1) The AIC+ module is recommended for isolation purposes when the terminal and controller are not on same power supply.