EasyManuals Logo

Allen-Bradley PowerFlex 20-750-DCBB2-F6 Programming Manual

Allen-Bradley PowerFlex 20-750-DCBB2-F6
548 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #107 background imageLoading...
Page #107 background image
Rockwell Automation Publication 750-PM001N-EN-P - February 2017 107
Drive Port 0 Parameters Chapter 3
PROTECTION
Predictive Maintenance
511 MchBrngTotalLife
Machine Bearing Total Life
Total number of hours expected over the life of the machine bearings.
Units:
Default:
Min/Max:
Hrs
Current Value
0.00 / 21474836.47
RW 32-bit
Integer
512 MchBrngElpsdLife
Machine Bearing Elapsed Life
Accumulated hours of machine bearing run time.
Use P472 [PredMaint Reset] to reset this parameter.
Units:
Default:
Min/Max:
Hrs
0.00
0.00 / 21474836.47
RO 32-bit
Integer
513 MchBrngRemainLif
Machine Bearing Remaining Life
Remaining number of hours until estimated end of life for machine bearings, and is the
difference between Machine Bearing Total Life and Machine Bearing Elapsed Life.
Use P472 [PredMaint Reset] to reset this parameter.
Units:
Default:
Min/Max:
Hrs
0.00
–21474836.48 / 21474836.47
RO 32-bit
Integer
514 MchBrngEventLvl
Machine Bearing Event Level
Percent of total expected machine bearing life for which an early warning alarm or fault
can be programmed.
Units:
Default:
Min/Max:
%
80.000
0.000 / 100.000
RW Real
515 MchBrngEventActn
Machine Bearing Event Action
Configures the response to a machine bearing event, which occurs when P514
[MchBrngEventLvl] is met or exceeded.
“Ignore” (0) – No action is taken.
Alarm” (1) – Type 1 alarm indicated.
“Flt Minor” (2) – Minor fault indicated. If running, drive continues to run.
Enable with P950 [Minor Flt Cfg]. If not enabled, acts like a major fault.
“FltCoastStop” (3) – Major fault indicated. Coast to Stop.
“Flt RampStop” (4) – Major fault indicated. Ramp to Stop.
“Flt CL Stop” (5) – Major fault indicated. Current Limit Stop.
Default:
Options:
0 = “Ignore”
0 = “Ignore”
1 = “Alarm”
2 = “Flt Minor”
3 = “FltCoastStop”
4 = “Flt RampStop
5 = “Flt CL Stop
RW 32-bit
Integer
516 MchBrngResetLog
Machine Bearing Reset Log
Total number of resets performed on the P512 [MchBrngElpsdLife] parameter.
Default:
Min/Max:
0
0 / 255
RO 32-bit
Integer
517 MchLubeElpsdHrs
Machine Lubricant Elapsed Hours
Accumulated machine hours since the most recent lubrication of the machine bearings.
Can be reset without restriction.
Use P472 [PredMaint Reset] to reset this parameter.
Units:
Default:
Min/Max:
Hrs
0.00
0.00 / 21474836.47
RO 32-bit
Integer
518 MchLube EventLvl
Machine Lubricant Event Level
Number of hours between scheduled lubrications of the machine bearings. Used for an
early warning alarm or fault according to P519 [MchLubeEventActn]. Event is disabled
when set to 0.
Units:
Default:
Min/Max:
Hrs
0.000
0.000 / 2147483648.000
RW Real
519 MchLubeEventActn
Machine Lubricant Event Action
Configures the response to a machine bearing lubrication event, which occurs when
P518 [MchLube EventLvl] is met or exceeded.
“Ignore” (0) – No action is taken.
Alarm” (1) – Type 1 alarm indicated.
“Flt Minor” (2) – Minor fault indicated. If running, drive continues to run.
Enable with P950 [Minor Flt Cfg]. If not enabled, acts like a major fault.
“FltCoastStop” (3) – Major fault indicated. Coast to Stop.
“Flt RampStop” (4) – Major fault indicated. Ramp to Stop.
“Flt CL Stop” (5) – Major fault indicated. Current Limit Stop.
Default:
Options:
0 = “Ignore”
0 = “Ignore”
1 = “Alarm”
2 = “Flt Minor”
3 = “FltCoastStop”
4 = “Flt RampStop
5 = “Flt CL Stop
RW 32-bit
Integer
File
Group
No. Display Name
Full Name
Description
Values
Read-Write
Data Type

Table of Contents

Other manuals for Allen-Bradley PowerFlex 20-750-DCBB2-F6

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allen-Bradley PowerFlex 20-750-DCBB2-F6 and is the answer not in the manual?

Allen-Bradley PowerFlex 20-750-DCBB2-F6 Specifications

General IconGeneral
BrandAllen-Bradley
ModelPowerFlex 20-750-DCBB2-F6
CategoryController
LanguageEnglish

Related product manuals