24 Rockwell Automation Publication 750-PM001N-EN-P - February 2017
Chapter 2 Parameter Organization
Advanced Parameter View (Port 0)
Parameter 301 [Access Level] set to option 1 “Advanced.
File Group Parameters
Monitor Metering Output Frequency 1
Commanded SpdRef 2
Mtr Vel Fdbk 3
Commanded Trq 4
Torque Cur Fdbk 5
Flux Cur Fdbk 6
Output Current 7
Output Voltage 8
Output Power 9
Output Powr Fctr 10
DC Bus Volts 11
DC Bus Memory 12
Elapsed MWH 13
Elapsed kWH 14
Elapsed Run Time 15
Elpsd Mtr MWHrs 16
Elpsd Rgn MWHrs 17
Elpsd Mtr kWHrs 18
Elpsd Rgn kWHrs 19
Drive Data Rated Volts 20 Rated Amps 21 Rated kW 22
Motor Control Motor Data Motor NP Volts 25
Motor NP Amps 26
Motor NP Hertz 27
Motor NP RPM 28
Mtr NP Pwr Units 29
Motor NP Power 30
Motor Poles 31
Mtr Ctrl Options Motor Ctrl Mode 35
Maximum Voltage 36
Maximum Freq 37
PWM Frequency 38
Mtr Options Cfg 40
Common Mode Type 41
Flux Up Enable 43
Flux Up Time 44
IPM Stc OfsTst K
(1)
1660
(1)
Frames 1…7 Only
Volts per Hertz Start Acc Boost 60
Run Boost 61
Break Voltage 62
Break Frequency 63
VHz Curve 65
Autotune Autotune 70
Autotune Torque 71
IR Voltage Drop 73
Ixo Voltage Drop 74
Flux Current Ref 75
Total Inertia 76
Inertia Test Lmt 77
IPM_Lg_25_pct 1630
IPM_Lg_50_pct 1631
IPM_Lg_75_pct 1632
IPM_Lg_100_pct 1633
IPM_Lg_125_pct 1634
IPM_Ld_0_pct 1635
IPM_Ld_100_pct 1636
Feedback & I/O Digin Functions Digital In Cfg 150
DI Enable 155
DI Clear Fault 156
DI Aux Fault 157
DI Stop 158
DI Cur Lmt Stop 159
DI Coast Stop 160
DI Start 161
DI Fwd Reverse 162
DI Run 163
DI Run Forward 164
DI Run Reverse 165
DI Jog 1 166
DI Jog 1 Forward 167
DI Jog 1 Reverse 168
DI Jog 2 169
DI Jog 2 Forward 170
DI Jog 2 Reverse 171
DI Manual Ctrl 172
DI Speed Sel 0 173
DI Speed Sel 1 174
DI Speed Sel 2 175
DI HOA Start 176
DI MOP Inc 177
DI MOP Dec 178
DI Accel 2 179
DI Decel 2 180
DI SpTqPs Sel 0 181
DI SpTqPs Sel 1 182
DI Stop Mode B 185
DI BusReg Mode B 186
DI PwrLoss ModeB 187
DI Pwr Loss 188
DI Precharge 189
DI Prchrg Seal 190
DI PID Enable 191
DI PID Hold 192
DI PID Reset 193
DI PID Invert 194
DI Torque StptA 195
DI Fwd End Limit 196
DI Fwd Dec Limit 197
DI Rev End Limit 198
DI Rev Dec Limit 199
DI PHdwr OvrTrvl 200
DI NHdwr OvrTrvl 201
Control Board IO
755
Digital In Sts 220
Digital Inputs
753
Digital In Sts 220 Dig In Filt Mask 222 Dig In Filt 223
Digital Outputs
753
Dig Out Sts 225
Dig Out Invert 226
Dig Out Setpoint 227
RO0 Sel 230
RO0 Level Sel 231
RO0 Level 232
RO0 Level CmpSts 233
RO0 On Time 234
RO0 Off Time 235
TO0 Sel 240
TO0 Level Sel 241
TO0 Level 242
TO0 Level CmpSts 243
TO0 On Time 244
TO0 Off Time 245
Motor PTC
753
PTC Cfg 250 PTC Status 251
Analog Inputs
753
Anlg In Type 255
Anlg In Sqrt 256
Anlg In Loss Sts 257
Anlg In0 Value 260
Anlg In0 Hi 261
Anlg In0 Lo 262
Anlg In0 LssActn 263
Anlg In0 Raw Val 264
Anlg In0 Filt Gn 265
Anlg In0 Filt BW 266
Analog Outputs
753
Anlg Out Type 270
Anlg Out Abs 271
Anlg Out0 Sel 275
Anlg Out0 Stpt 276
Anlg Out0 Data 277
Anlg Out0 DataHi 278
Anlg Out0 DataLo 279
Anlg Out0 Hi 280
Anlg Out0 Lo 281
Anlg Out0 Val 282
R0 Predict Main
753
RO PredMaint Sts 285
RO0 Load Type 286
RO0 Load Amps 287
RO0 TotalLife 288
RO0 ElapsedLife 289
RO0 RemainLife 290
RO0 LifeEvntLvl 291
RO0 LifeEvntActn 292
Monitor
Motor Control
Feedback and IO

Table of Contents

Other manuals for Allen-Bradley PowerFlex 20-750-DCBB2-F6

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allen-Bradley PowerFlex 20-750-DCBB2-F6 and is the answer not in the manual?

Allen-Bradley PowerFlex 20-750-DCBB2-F6 Specifications

General IconGeneral
BrandAllen-Bradley
ModelPowerFlex 20-750-DCBB2-F6
CategoryController
LanguageEnglish

Related product manuals