Rockwell Automation Publication 750-PM001N-EN-P - February 2017 73
Drive Port 0 Parameters Chapter 3
File
Group
No. Display Name
Full Name
Description
Values
Read-Write
Data Type
FEEDBACK & I/O
Digital Outputs
225 Dig Out Sts
Digital Output Status
RO 16-bit
Integer
Status of the digital outputs.
226 Dig Out Invert
Digital Output Invert
RO 16-bit
Integer
Inverts the selected digital output.
227 Dig Out Setpoint
Digital Output Setpoint
RO 16-bit
Integer
Controls Relay or Transistor Outputs when chosen as the source. Can be used to control outputs from a communication device using DataLinks.
230 RO0 Sel
Relay Output 0 Select
Selects the source that will energize the relay output.
Any status parameter bit can be used as an output source. For example P935 [Drive
Status 1] Bit 7 “Faulted.
Default:
Min/Max:
0
0 / 159999.15
RW 32-bit
Integer
231 RO0 Level Sel
Relay Output 0 Level Select
Selects the source of the level that will be compared.
Default:
Min/Max:
0
0 / 159999
RW 32-bit
Integer
232 RO0 Level
Relay Output 0 Level
Sets the level compare value.
Default:
Min/Max:
0.0
–/+1000000.0
RW Real
753
Options
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Trans Out 0
Relay Out 0
Default0000000000000000
Bit 1514131211109876543210
0 = Condition False
1 = Condition True
753
Options
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Trans Out 0
Relay Out 0
Default0000000000000000
Bit 1514131211109876543210
0 = Condition False
1 = Condition True
753
Options
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Trans Out 0
Relay Out 0
Default0000000000000000
Bit 1514131211109876543210
0 = Condition False
1 = Condition True
753
753
753

Table of Contents

Other manuals for Allen-Bradley PowerFlex 20-750-DCBB2-F6

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allen-Bradley PowerFlex 20-750-DCBB2-F6 and is the answer not in the manual?

Allen-Bradley PowerFlex 20-750-DCBB2-F6 Specifications

General IconGeneral
BrandAllen-Bradley
ModelPowerFlex 20-750-DCBB2-F6
CategoryController
LanguageEnglish

Related product manuals