EasyManua.ls Logo

Allen-Bradley PowerFlex 700S - Page 36

Allen-Bradley PowerFlex 700S
118 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
36 Rockwell Automation Publication 20D-TD002L-EN-P - July 2018
PowerFlex 700S Drives with Phase II Control
600V Shielded/Unshielded Cable - Meters (Feet)
13
1000
(2)
2 12.2
(40)
30.5
(100)
61.0
(200)
121.9
(400)
12.2
(40)
45.7
(150)
61.0
(200)
121.9
(400)
45.7
(150)
152.4
(500)
304.8
(1000)
365.8
(1200)
2x
1321-3R600-B
20 525
(5)
1200
(
2)
2 12.2
(40)
30.5
(100)
61.0
(200)
121.9
(400)
12.2
(40)
45.7
(150)
61.0
(200)
121.9
(400)
45.7
(150)
152.4
(500)
304.8
(1000)
365.8
(1200)
2x
1321-3R750-B
20 525
(5)
1250
(
2)
2 12.2
(40)
30.5
(100)
61.0
(200)
121.9
(400)
12.2
(40)
45.7
(150)
61.0
(200)
121.9
(400)
45.7
(150)
152.4
(500)
304.8
(1000)
365.8
(1200)
2x
1321-3R750-B
20 525
(5)
(1) Frame 12 drives have dual inverters and require two output reactors. The resistor ratings are per phase values for each reactor.
(2) Some Frame 13 drives require two output reactors to match drive amp rating. The resistor ratings are per phase values for each reactor.
(3) Resistor specification is based on two cables per phase.
(4) Resistor specification is based on three cables per phase.
(5) Resistor specification is based on four cables per phase.
Drive No Solution Reactor Only Reactor + Damping Resistor
or 1321-RWR
Reactor/RWR Resistor Available Options
Frame HP kHz 1488V 1850V 1488V 1850V 1488V 1850V Cat. No. Ohms Watts
TFA1
TFB2
RWR2
RWC
1 1 2/4 30.5 (100) 121.9 (400) 121.9 (400) 121.9 (400) 121.9 (400) 121.9 (400)
lll
2 2/4 30.5 (100) 152.4 (500) 121.9 (400) 152.4 (500) 152.4 (500) 152.4 (500)
llll
3 2/4 30.5 (100) 152.4 (500) 121.9 (400) 182.9 (600) 182.9 (600) 182.9 (600)
llll
5 2/4 30.5 (100) 152.4 (500) 121.9 (400) 243.8 (800) 243.8 (800) 243.8 (800) 1321-RWR8-EP
llll
7.5 2/4 30.5 (100) 152.4 (500) 121.9 (400) 304.8 (1000) 304.8 (1000) 304.8 (1000) 1321-RWR8-EP
ll
10 2/4 30.5 (100) 152.4 (500) 121.9 (400) 365.8 (1200) 365.8 (1200) 365.8 (1200) 1321-RWR12-EP
ll
15 2/4 30.5 (100) 152.4 (500) 121.9 (400) 365.8 (1200) 365.8 (1200) 365.8 (1200) 1321-RWR18-EP
l
2 20 2/4 30.5 (100) 152.4 (500) 121.9 (400) 365.8 (1200) 365.8 (1200) 365.8 (1200) 1321-RWR25-EP
l
25 2/4 30.5 (100) 152.4 (500) 121.9 (400) 365.8 (1200) 365.8 (1200) 365.8 (1200) 1321-RWR25-EP
l
3 30 2/4 30.5 (100) 152.4 (500) 121.9 (400) 365.8 (1200) 365.8 (1200) 365.8 (1200) 1321-RWR35-EP
l
40 2/4 30.5 (100) 152.4 (500) 121.9 (400) 365.8 (1200) 365.8 (1200) 365.8 (1200) 1321-RWR45-EP
l
50 2/4 36.6 (120) 152.4 (500) 121.9 (400) 365.8 (1200) 365.8 (1200) 365.8 (1200) 1321-RWR55-EP
l
4 60 2/4 36.6 (120) 152.4 (500) 121.9 (400) 365.8 (1200) 365.8 (1200) 365.8 (1200) 1321-RWR80-EP
l
5 75 2/4 36.6 (120) 152.4 (500) 121.9 (400) 365.8 (1200) 365.8 (1200) 365.8 (1200) 1321-RWR80-EP
l
100 2/4 42.7 (140) 152.4 (500) 121.9 (400) 304.8 (1000) 365.8 (1200) 365.8 (1200) 1321-RWR100-EP
l
6 125 2/4 42.7 (140) 152.4 (500) 121.9 (400) 304.8 (1000) 365.8 (1200) 365.8 (1200) 1321-RWR130-EP
l
150 2/4 42.7 (140) 152.4 (500) 121.9 (400) 304.8 (1000) 365.8 (1200) 365.8 (1200) 1321-RWR160-EP
l
9 150 2 42.7 (140) 152.4 (500) 61.0 (200) 304.8 (1000) 365.8 (1200) 365.8 (1200) 1321-RWR200-EP
l
200 2 42.7 (140) 152.4 (500) 61.0 (200) 304.8 (1000) 365.8 (1200) 365.8 (1200) 1321-RWR250-EP
l
10 250 2 42.7 (140) 152.4 (500) 61.0 (200) 304.8 (1000) 365.8 (1200) 365.8 (1200) 1321-3RB250-B 50 315
l
350 2 42.7 (140) 152.4 (500) 61.0 (200) 304.8 (1000) 365.8 (1200) 365.8 (1200) 1321-3RB350-B 20 585
(3)
(3) Resistor specification is based on two cables per phase.
l
400 2 42.7 (140) 152.4 (500) 61.0 (200) 304.8 (1000) 365.8 (1200) 365.8 (1200) 1321-3RB400-B 20 585
(3)
l
450 2 42.7 (140) 152.4 (500) 61.0 (200) 304.8 (1000) 365.8 (1200) 365.8 (1200) 1321-3R500-B 20 585
(3)
l
11 500 2 42.7 (140) 152.4 (500) 61.0 (200) 304.8 (1000) 365.8 (1200) 365.8 (1200) 1321-3R500-B 20 585
(3)
l
600 2 42.7 (140) 152.4 (500) 61.0 (200) 304.8 (1000) 365.8 (1200) 365.8 (1200) 1321-3R600-B 20 585
(3)
l
12
(1)
(1) Frame 12 drives have dual inverters and require two output reactors. The resistor ratings are per phase values for each reactor.
700 2 42.7 (140) 152.4 (500) 61.0 (200) 304.8 (1000) 365.8 (1200) 365.8 (1200) 2 X 1321-3RB320-B 40 300
(3)
l
800 2 42.7 (140) 152.4 (500) 61.0 (200) 304.8 (1000) 365.8 (1200) 365.8 (1200) 2 X 1321-3RB400-C 40 480
(4)
(4) Resistor specification is based on three cables per phase.
l
900 2 42.7 (140) 152.4 (500) 61.0 (200) 304.8 (1000) 365.8 (1200) 365.8 (1200) 2 X 1321-3R400-B 40 480
(4)
13 1000 2 42.7 (140) 152.4 (500) 61.0 (200) 304.8 (1000) 365.8 (1200) 365.8 (1200) 1321-3R1000-C 20 960
(4)
1100 2 42.7 (140) 152.4 (500) 61.0 (200) 304.8 (1000) 365.8 (1200) 365.8 (1200) 1321-3R1000-B 10 1440
(5)
(5) Resistor specification is based on four cables per phase.
1300
(2)
(2) Some Frame 13 drives require two output reactors to match drive amp rating. The resistor ratings are per phase values for each reactor.
2 42.7 (140) 152.4 (500) 61.0 (200) 304.8 (1000) 365.8 (1200) 365.8 (1200) 2 X 1321-3R600-B 20 720
(5)
480V Shielded/Unshielded Cable - Meters (Feet) (continued)
Drive No Solution Reactor Only Reactor + Damping Resistor or
1321-RWR
Reactor/RWR Resistor Available Options
Frame HP kHz 1000V 1200V 1488V 1600V 1000V 1200V 1488V 1600V 1000V 1200V 1488V 1600V Cat. No. Ohms Watts
TFA1
TFB2
RWR2
RWC

Other manuals for Allen-Bradley PowerFlex 700S

Related product manuals