Rockwell Automation Publication 20D-TD002L-EN-P - July 2018 47
PowerFlex 700S Drives with Phase II Control
Power Terminal Block Details, Continued
Terminal Description Notes
BR1 DC Brake (+) Dynamic Brake Resistor Connection (+)
BR2 DC Brake (–) Dynamic Brake Resistor Connection (–)
DC+ DC Bus (+) DC Input Power or Dynamic Brake Chopper
DC– DC Bus (–) DC Input Power or Dynamic Brake Chopper
PE PE Ground Not present on 3 Frame drives
Motor Ground Not present on 3 Frame drives
PS+ Aux +
(1)
(1) External control power: UL Installation - 300V DC, ±10%, Non UL Installation - 270-600V DC, ±10%. Frame 1…3, 40 W, 165 mA, Frame 5, 80 W, 90 mA
PS- Aux -
(1)
U U (T1) To motor
V V (T2) To motor
W W (T3) To motor
R R (L1) AC Line Input Power
S S (L2) AC Line Input Power
T T (L3) AC Line Input Power
DC–DC+BR1BR2
USE 75 C COPPER WIRE ONLY, TORQUE 52 IN-LB (6 N-M)
22-10
AWG
5.3 IN-LB
(0.6 N-M)
WIRE STRIP
PS+
PS–
U
T1
V
T2
W
T3
PE PE
USE 75 C
COPPER WIRE
ONLY
TORQUE
52 IN-LB
(6 N-M)
OUTPUT
22-10 AWG
5.3 IN-LB
(0.6 N-M)
FAN
INPUT
1-PHASE
0 VAC
120 VAC
240 VAC
Precharge Resistor Fuse – FWP-15A14F
(Common Bus Drives w/Precharge Only)
Common Mode Capacitor
& MOV Jumpers
Input Filter Capacitor
USE 75 C
COPPER WIRE
ON LY
TOR QUE
52 IN-LB
(6 N-M)
U
T1
DC–DC+BR1BR2
V
T2
W
T3
R
L1
S
L2
INPUTOUTPUT
T
L3
PE PE
USE 75 C COPPER WIRE ON LY, T OR QUE 52 IN-LB (6 N-M)
22-10
AWG
5.3 IN-LB
(0.6 N-M)
WIRE STRIP
PS+
PS–
Common Mode Capacitor
& MOV Jumpers
Input Filter Capacitor
L1
AC Line Input Power To Motor Leads
L2 L3 L1 L2 L3 U/T1 V/T2 W/T3 U/T1 V/T2 W/T3
Shaded terminals (BR1 & BR2) will only be present on drives that are ordered with the Brake option.
Frame 6 - 150 HP
Normal Duty
480V AC Input
Frame 6 -150 HP
Normal Duty
650V DC Input
0V AC
240V AC
120V AC
Frame 9