Gas Requirements
62
©
Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT Part No. 70458301ENR7
030 Series M4703P3
T30 Series M4707P3
035 Series M4711P3
T45 Series M4880P3
055 Series M4924P3
CE GASES refer to Installing CE Gas Drying Tumble Dryers
section, the above data does not apply to the CE.
Turn on gas and check all pipe connections (internal and
external) for gas leaks with a non-corrosive leak detection fluid.
Purge air in gas service line by operating the tumble dryers in
the drying mode. If burner does not light and unit goes into
lockout, open and close the door and restart. Repeat these steps
until burner ignites. Use pipe compound, resistant to actions of
L.P. gas, on all pipe threads.
WARNING
Check all pipe connections, internal and external,
for gas leaks using a non-corrosive leak detection
fluid. To reduce the risk of explosion or fire, DO
NOT USE AN OPEN FLAME TO CHECK FOR GAS
LEAKS! Gas connections should be checked twice
a year for leakage.
W635
1
Gas Line to Tumble Dryer
2
Gas Supply Piping System
3
Gas "T" Fitting
4
3 in. (76 mm) Minimum Gas Pipe
5
Gas Pipe Cap
6
Sediment Trap
Figure 22