Global Menu List Options
Display Description Default
DURATION 1-120 seconds
NETWORK NODE NUMBER Identification number for networked ma-
chine
ERRORS Allows some error displays to be turned
on/off
BACK Return to previous menu
LIMIT CYCLES DISPLAY Turn limit cycles display on/off DISABLE
MOISTURE SENSOR ERR DISP Turn moisture sensor error on/off ENABLE
FALSE FLAME ERR DISP Turn false flame error display on/off DISABLE
ALLOW ERROR CLEARING ENABLE/DISABLE ENABLE
COOL DOWN Global cool down programming parame-
ters
BACK Return to previous menu
TIME Amount of time cool down will last during
each cycle
2
TEMPERATURE Temperature that when reached will end
cool down
70°F [22°C] - 110°F [43°C]
100°F [38°C]
CYCLE TEMPERATURES Global cycle temperature parameters
BACK Return to previous menu
HIGH 155°F [68°C] - 190°F [88°C] 190°F [88°C]
MEDIUM 135°F [57°C] - 165°F [74°C] 160°F [71°C]
LOW 105°F [41°C] - 155°F [68°C] 140°F [60°C]
VERY LOW 100°F [38°C] - 120°F [49°C] 120°F [49°C]
TEMPERATURE UNITS Fahrenheit (°F) or Celsius (°C) °F
AUTO-IGNITE RETRY Number of retry attempts before heater er-
ror is declared: 0-255
3
REAL-TIME CLOCK
BACK Return to previous menu
SET CLOCK MINUTES 00 - 59
SET CLOCK HOURS 00 - 23
SET CLOCK DAY 01 - 07
SET CLOCK DATE 01 - 31