Maintenance
49
F8410701 (EN)
c. Verify that V-belts are properly aligned by
checking pulley alignment. Motor pulley
should align with end of motor shaft to align
belts.
1. Install belt on basket sheave.
2. Install belt on motor pulley.
3. Insert belt in appropriate motor pulley
grooves so belt rides on the center of the
basket sheave.
4. Check overflow hose and drain hose for leaks.
5. Check the supply dispenser hoses and hose
connections.
6. Clean inlet hose filter screens:
a. Turn water off and allow valve to cool, if
necessary.
b. Unscrew inlet hose and remove filter screen.
c. Clean with soapy water and reinstall. Replace
if worn or damaged.
7. Tighten motor mounting bolt locknuts and
bearing bolt locknuts, if necessary.
8. Use compressed air to clean lint from motor.
9. Clean interior of machine, both basket and shell,
by wiping with a water-soaked sponge or cloth.
10. Use compressed air to ensure that all electrical
components are free of moisture and dust.
11. Remove chemical supply components (where
applicable) and check for residual chemicals.
Clean or replace as necessary.
Quarterly
NOTE: Disconnect power to the machine before
performing the quarterly maintenance procedures.
1. Tighten door hinges and fasteners, if necessary.
2. Tighten anchor bolts, if necessary.
3. Verify that the drain motor shield is in place and
secure.
4. Check all painted surfaces for bare metal.
(Matching gray paint is available from the
manufacturer.)
If bare metal is showing, paint with primer
or solvent-based paint.
If rust appears, remove it with sandpaper or
by chemical means.
Then paint with primer or solvent-based paint.
5. Clean steam filter, where applicable.
a. Turn off steam supply and allow time for the
valve to cool.
b. Unscrew nut.
c. Remove element and clean.
d. Replace element and nut.
6. Place a large magnet over the normally-closed
ball switch to verify the out-of-balance safety
switch operation.

Table of Contents