6. Apply probes to terminals 1 and 2 with door closed. The me-
ter should read “infinite”.
7. Open door. Meter should read “infinite” between 1 and 3 and
“zero” between 1 and 2.
Thermistor
1. While supporting the access panel, remove two screws from
bottom edge of access panel.
2. Gently lower the access panel to disengage panel locators
from bottom edge of front panel.
3. Label and disconnect wires from thermistor.
NOTE: Refer to wiring diagram when rewiring ther-
mistor.
4. Set meter to read Ohms.
5. Apply meter probes to the thermistor terminals.
6. Meter should read that resitance is present (thermistor is not
open).
Test Procedures
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
63 Part No. D515519R3