NetMaster Troubleshooting
58.No IR Communication
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the tumble dryer before servicing.
Close gas shut-off valve to gas tumble dryer before servicing.
Close steam valve to steam tumble dryer before servicing.
Never start the tumble dryer with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumble dryer is properly grounded.
W002R1
WARNING
IR Communication
Check the
following:
- IR com
m
unication disabled
by
manual programm
ing.
- Is the IR window on the control
covered or blocked.
- if needed, change control
board.
Check the following:
- low battery on microwand
- is the IR window covered or
blocked on the control.
- if needed replace the electronic
control
- is the IR cap properly attached to
the microwand.
Communication
sequence checks
out.
Attempt to
communicate with
the electronic
control from the
microwand.
Aim microwand
closer and try again.
Is there a respons
e of
any kind from the
electronic control?
Does the control
respond?
Does the electronic
control display E:O
F
or -C-?
NO
YES
-C-
"E:OF"
NO
YES
Single and stacked.
Gas and electric heat.
Single and three phase
power supply.
No IR Communication
TMB247S
TMB247S

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ALLIANCE T30 Series and is the answer not in the manual?

ALLIANCE T30 Series Specifications

General IconGeneral
BrandALLIANCE
ModelT30 Series
CategoryDryer
LanguageEnglish

Related product manuals