EasyManuals Logo

Allied Telesis AT-GS924MX User Manual

Allied Telesis AT-GS924MX
118 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #114 background imageLoading...
Page #114 background image
Appendix A: Technical Specifications
114
Ventilation
Environmental Specifications
Power Specifications
Input Voltages
Table 13. Ventilation Requirements
Recommended Minimum
Ventilation on All Sides
10 cm (4.0 in)
Table 14. Environmental Specifications
Operating Ambient Temperature 0° C to 50° C (32° F to 113° F)
Storage Temperature -25° C to 70° C (-13° F to 158° F)
Operating Humidity 5% to 90% noncondensing
Storage Humidity 5% to 95% noncondensing
Maximum Operating Altitude
AT-GS924MX: 2,000 m (6,562 ft)
AT-GS924MPX: 3,000 m (9,842 ft)
AT-GS948MX: 2,000 m (6,562 ft)
AT-GS948MPX: 3,000 m (9,842 ft)
Maximum Nonoperating Altitude 4,000 m (13,100 ft)
Table 15. Input Voltages
AT-GS924MX AC model: 100-240 VAC, 1.0A
maximum, 50/60 Hz
AT-GS924MPX AC model: 100-240 VAC, 5.0A
maximum, 50/60 Hz
AT-GS948MX AC model: 100-240 VAC, 1.0A
maximum, 50/60 Hz
AT-GS948MPX AC model: 100-240 VAC, 5.0A
maximum, 50/60 Hz