Allied A96US2V - Blower Performance Data (Models 110;135); A96 US2 V110 C20 S Blower Performance

Allied A96US2V
80 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
507404-02 Page 55 of 80Issue 1448
HEATING
1
Heating Speed Dip
Switch Setting First Stage heating Speed - cfm Second Stage Heating Speed-cfm
+24% 1520 2015
+18% 1445 1920
+12% 1370 1820
+6% 1300 1725
Fauctory Default 1225 1625
-6% 1150 1530
-12% 1080 1430
-18% 1005 1335
COOLING
1
Cooling Speed DIP
Switch Settings
First Stage Cooling Speed -cfm Second Stage Cooling Speed-cfm
Low Medium-Low Medium-High
2
High Low Medium-Low Medium-High
2
High
+ 935 1075 1240 1405 1320 1540 1760 2010
Factory 850 975 1125 1275 1200 1400 1600 1825
- 765 880 1015 1150 1080 1260 1440 1645
A96US2V110C20S BLOWER PERFORMANCE (less lter)
0 through 0.8 in. w.c. (Heating) and 0 through 1.0 in. w.c. (Cooling) External Static Pressure Range
HEATING
1
Heating Speed Dip
Switch Setting First Stage heating Speed - cfm Second Stage Heating Speed-cfm
+24% 1705 2080
+18% 1625 1980
+12% 1540 1875
+6% 1460 1775
Fauctory Default 1375 1675
-6% 1295 1575
-12% 1210 1475
-18% 1130 1375
COOLING
1
Cooling Speed DIP
Switch Settings
First Stage Cooling Speed -cfm Second Stage Cooling Speed-cfm
Low Medium-Low Medium-High
2
High Low Medium-Low Medium-High
2
High
+ 935 1075 1240 1405 1320 1540 1760 2010
Factory 850 975 1125 1275 1200 1400 1600 1825
- 765 880 1015 1150 1080 1260 1440 1645
A96US2V135D20S BLOWER PERFORMANCE (less lter)
0 through 0.8 in. w.c. (Heating) and 0 through 1.0 in. w.c. (Cooling) External Static Pressure Range
1
Cooling and Heating speed are based on a combination of DIP switch setting on the furnace control. Refer to installation instructon for specic DIP
Switch settings
2
Factory default setting
NOTES: The effect of static pressure is included in air volumes shown.
First stage Cool (two stage air conditioning units only) is approximately 70% of the same second stage COOL speed position
Continous Fan Only speed approximately 50% of the selected second stage cooling speed - minimum 500cfm.
1
Cooling and Heating speed are based on a combination of DIP switch setting on the furnace control. Refer to installation instructon for specic DIP
Switch settings
2
Factory default setting
NOTES: The effect of static pressure is included in air volumes shown.
First stage Cool (two stage air conditioning units only) is approximately 70% of the same second stage COOL speed position
Continous Fan Only speed approximately 50% of the selected second stage cooling speed - minimum 500cfm.