EasyManua.ls Logo

Alltrax AC1 - Code Definitions; Error Code Explanations

Alltrax AC1
34 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
31
http://www.alltraxinc.com
Error Code Denitions:
• Short Circuit/Output Fault:
Controller detected a short circuit or other fault on the output circuit.
Check wiring.
• Battery Under Voltage:
B+ Voltage lower than Low Voltage Battery Setting. Check pack
voltage or program settings.
• Battery Over Voltage:
B+ Voltage Higher than Over Voltage Battery Setting. Check pack
voltage or program settings
• Over temperature:
Busbar temperature exceeds 90
o
C. Let controller cool and/or add fan.
• Throttle power Fault:
This is a 5V fault, if the speed sensor gets damaged this alarm will be
one of the alarms triggered. Can also be caused by a fault in voltage
based throttles
• Pre-charge Failure:
B+voltageandKSIvoltagedierbymorethan5v.Stucksolenoid.
• Under Temp:
Busbar Temperature reads less than -20
o
C
• High Throttle Over range & High Throttle Under range:
High Side of throttle signal is outside of acceptable window for that
throttle type. Check and/or replace throttle. Change throttle type to
correct throttle installed on car.
• Low Throttle Over range & Low Throttle Under range:
Low Side of throttle signal is outside of acceptable window for that
throttle type. Check and/or replace throttle. Change throttle type to
correct throttle installed on car.
• Bad Variable Set Loaded:
Alltrax loaded variable data is missing or corrupted. Contact Alltrax
• Throttle/Brake Range:
The RXV has a “throttle” built into the brake pedal to communicate
with the motor brake. This alarm indicates an error in that signal.
CODE DEFINITIONS