PAGE 78 ALMAC s.r.l.
6.2.2 Visual and structural inspection
Visually check the following points according to the schedule indicated in the
general chart. Immediately inform a maintenance technician if faults are
discovered.
Frame state;
State of the bi-levelling structure and of the tracked chassis;
In particular check if there is any rust in the structure;
State of the rubber tracks;
Oil leaking;
Pins and stop devices.
6.2.3 Damage to tubes and cables
Visually check at the frequencies indicated in the general chart to make sure
that the articulation point of the hydraulic hoses and electric cables are not
misshapen or damaged. Examples of such faults are shown on the photos below.
Damaged hydraulic hose pipe
Damaged electric cable