SVP INSTRUCTION MANUAL Page 19
SHAW-ALMEX INDUSTRIES LIMITED 49909-010
Jun 2017
replace parts as required.
2. Leaking pressure bag or hose.
2. Remove the pressure bag and inspect for leaks. If no leak
is evident, use compressed air to inflate the bag
(maximum 5 p.s.i./ 0.35 kg/cm2) and spray soapy water
over the bag. Bubbling will indicate escaping air and the
bag should be replaced.
7.5. Platens not Cooling
Refer to Pressure Pump manual first. If the fault is not found, use the following procedure.
1. Blocked fluid passage.
1. Remove the cooling hoses and check for obstruction.
Clean or replace parts as required. Blow compressed air
through the cooling channels from one cooling port and
then from the other to check for obstruction within the
platen. If there is an obstruction that does not clear, call
SHAW-ALMEX for service.
8. SERVICE
8.1. Emergency Service
Contact: Service Department
Telephone: 705 746 5884
1 800 461 4351 (Canada and U.S. only)
Fax: 705 746 9484
Mail: SHAW-ALMEX INDUSTRIES LIMITED
P.O. Box 430
Parry Sound, Ontario
Canada, P2A 2X4
E-mail: service@almex.com
8.2. Return of Goods Authorization
The service department of Shaw-Almex Industries Limited MUST be contacted for the necessary authorization
and documentation prior to returning goods to the factory.
The service department may be reached at the above numbers.
8.3. Guarantee
Your ALMEX vulcanizer is guaranteed against defective parts, material and workmanship for a period of 12
months from the date of purchase. For complete details, refer to the Warranty Card.