3.1.3. Hot Surface, Burning Hazard
1. The platen surfaces typically operate at or above 300 F (150 C). Touching these surfaces will result in a
burn.
2. The cooling water will discharge from the platen initially as steam creating a burning hazard. Ensure the
cooling water discharge is not directed at any person or injury could result.
3. Always use an Almex temperature controller when operating the vulcanizer and never leave the vulcanizer
operating while unattended. Improper use or component failure could result in the vulcanizer overheating.
3.1.4. Electrical Hazard
1. A qualified electrician should perform all maintenance of the electrical components of the vulcanizer.
2. All of the electrical components contain live circuits. Do not open or service any of the electrical equipment
without disconnecting the main power supply.
3. Incorrect voltage and phase may result in component damage and create a fire hazard.
4. Equipment power supplies must be properly grounded or a severe shocking hazard may result.
5. Avoid using equipment in wet surroundings or a severe shocking hazard may result.
6. If any cables or connectors are damaged, they must be replaced or a fire and shock hazard may result.
3.2. Limitation of use
This equipment has been designed to vulcanize conveyor belts. The process of vulcanizing is done by applying a
combination of heat and pressure on the product for a certain period of time.
The SVP vulcanizer may operate at up to 200 psi [1380 kPa]. Refer to the rating label on the traverse bar for the
maximum pressure of the specific unit. The press is designed for connection to an ALMEX pressure control unit
that is generally supplied complete with a pressure hose. A continuous pressure supply must not be connected to
the press.
The recommended maximum operating temperature is 325 F (165 C) for long life of the heating element and
platen insulation. The press is designed for connection to an ALMEX temperature control panel that is supplied
complete with platen electrical cables.
Hoses have been provided to connect a cooling supply to the press.
Never leave the vulcanizer operating while unattended. Other use is not allowed without the written permission
of Shaw-Almex.
3.3. Hazardous Materials and Products
The cooling water may discharge from the platen initially as steam creating a burning hazard. Ensure the cooling
water discharge is not directed at any person or injury could result.
There could be hazards associated with the vulcanizing materials. Consult the splicing material specification for
details.
3.4. Safe Handling
Handling the machine does present some residual hazard. The weight of the components is marked on the
components. Hoisting equipment may be needed to position the platens and traverse bars in place. Approved
hoisting slings will be required.
Wear protective footwear when handling the press.
Connection of cables and hoses must be made in such a way that no tripping hazard is created.